Trace a block along one bolt line and across the nearest side edge. The tension ligament deducts half a hole.
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
ANSI/AISC 360-22B4.3 · D2 · J4.3
Inputs
LRFD
Use loads and strengths from the selected method. Re-enter values after switching methods.
Gusset rupture paths
Within modeled limits
Block shear
86.801kip
Net tension
67.289kip
Gross yield
60.75kip
Net hole
0.875in
Crimson shows the selected block path. Blue marks the gross-width tension section through the last bolt row.
Calculation results
Limit state
Demand
Available
Use
Gross yielding
28 kip
60.75 kip
46.1%
Net tension rupture
28 kip
67.289 kip
41.6%
Block shear rupture
28 kip
86.801 kip
32.3%
Calculation values
Nominal hole diameter
0.813 in
Side edge distance
2.5 in
Gross tension area Aᵍ
1.875 in²
Net tension area Aₙ
1.547 in²
Effective net area Aₑ
1.547 in²
Block tension area Aₙₜ
0.773 in²
Gross shear area Aᵍᵥ
3.281 in²
Net shear area Aₙᵥ
2.133 in²
Nominal gross yielding
67.5 kip
Nominal net rupture
89.719 kip
Shear yielding term
70.875 kip
Shear rupture term
74.222 kip
Block tension term
44.859 kip
Nominal block shear Rₙ
115.734 kip
SteelBeamLab / AISC 360-22 B4.3 · D2 · J4.3
One bolt line with a single edge rupture path
LRFD · US customary
Use a centered, unstaggered grid with straight load and rupture paths. Assess other plausible paths, gusset stability, and fastener resistance separately.
Entered values
Overall plate width
5 in
Plate thickness t
0.375 in
Steel yield stress Fᵧ
36 ksi
Plate tensile stress Fᵤ
58 ksi
Required tension Pᵣ
28 kip
Nominal bolt diameter
3/4 in
Rows along load
4
Lines across plate
1
Row pitch
2.5 in
Transverse gage
3 in
Loaded end distance
1.25 in
Block shear path
Edge path · One plane
Shear lag factor U
1
Block tension Uᵦₛ
1.0 · Uniform
Key results
Block shear
86.801kip
Net tension
67.289kip
Gross yield
60.75kip
Net hole
0.875in
Limit-state screening
Limit state
Demand
Available
Use
Gross yielding
28 kip
60.75 kip
46.1%
Net tension rupture
28 kip
67.289 kip
41.6%
Block shear rupture
28 kip
86.801 kip
32.3%
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
Worked solution at the starting values
Use the enlarged net-width hole deduction of 0.875 in and calculate Aₑ = 1.547 in².
Evaluate the block with net shear area 2.133 in² and net tension area 0.773 in².
Compare the three available strengths. Gross yielding governs at 60.75 kip.
Calculation basis
Use a centered, unstaggered grid with straight load and rupture paths. Assess other plausible paths, gusset stability, and fastener resistance separately.
Hole and tension areas
For inch-series standard holes, the net deduction is the nominal J3.3 hole diameter plus 1/16 in per B4.3. This is dᵦ + 1/8 in through 7/8-in bolts and dᵦ + 3/16 in for 1-in and larger bolts. Aₑ = UAₙ. D2 compares FᵧAᵍ and FᵤAₑ with their separate design factors.
Block path geometry
The U path runs along both outside bolt lines and across the last row. The edge path runs along one outside bolt line and across the nearest side ligament. Each shear plane deducts n − ½ enlarged holes. The tension path counts half a hole at each intersected end plus whole interior holes.
J4.3 rupture
Rₙ = min(0.60FᵤAₙᵥ, 0.60FᵧAᵍᵥ) + UᵦₛFᵤAₙₜ. Use Uᵦₛ = 1.0 for uniform tension stress or 0.5 for nonuniform stress. Apply φ = 0.75 or Ω = 2.00.