Use a shallow single-row block and a wide plate. The short shear path governs even with substantial gross tension area.
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
ANSI/AISC 360-22B4.3 · D2 · J4.3
Inputs
LRFD
Use loads and strengths from the selected method. Re-enter values after switching methods.
Gusset rupture paths
Limit exceeded
Block shear
22.389kip
Net tension
183.516kip
Gross yield
157.95kip
Net hole
0.875in
Crimson shows the selected block path. Blue marks the gross-width tension section through the last bolt row.
Calculation results
Limit state
Demand
Available
Use
Gross yielding
54 kip
157.95 kip
34.2%
Net tension rupture
54 kip
183.516 kip
29.4%
Block shear rupture
54 kip
22.389 kip
241.2%
Calculation values
Nominal hole diameter
0.813 in
Side edge distance
5.425 in
Gross tension area Aᵍ
4.875 in²
Net tension area Aₙ
4.219 in²
Effective net area Aₑ
4.219 in²
Block tension area Aₙₜ
0.478 in²
Gross shear area Aᵍᵥ
0.788 in²
Net shear area Aₙᵥ
0.459 in²
Nominal gross yielding
175.5 kip
Nominal net rupture
244.688 kip
Shear yielding term
17.01 kip
Shear rupture term
15.986 kip
Block tension term
13.866 kip
Nominal block shear Rₙ
29.852 kip
SteelBeamLab / AISC 360-22 B4.3 · D2 · J4.3
Short gusset path with block shear governing
LRFD · US customary
Use a centered, unstaggered grid with straight load and rupture paths. Assess other plausible paths, gusset stability, and fastener resistance separately.
Entered values
Overall plate width
13 in
Plate thickness t
0.375 in
Steel yield stress Fᵧ
36 ksi
Plate tensile stress Fᵤ
58 ksi
Required tension Pᵣ
54 kip
Nominal bolt diameter
3/4 in
Rows along load
1
Lines across plate
2
Row pitch
3 in
Transverse gage
2.15 in
Loaded end distance
1.05 in
Block shear path
U path · Two planes
Shear lag factor U
1
Block tension Uᵦₛ
0.5 · Nonuniform
Key results
Block shear
22.389kip
Net tension
183.516kip
Gross yield
157.95kip
Net hole
0.875in
Limit-state screening
Limit state
Demand
Available
Use
Gross yielding
54 kip
157.95 kip
34.2%
Net tension rupture
54 kip
183.516 kip
29.4%
Block shear rupture
54 kip
22.389 kip
241.2%
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
Worked solution at the starting values
Use the enlarged net-width hole deduction of 0.875 in and calculate Aₑ = 4.219 in².
Evaluate the block with net shear area 0.459 in² and net tension area 0.478 in².
Compare the three available strengths. Block shear rupture governs at 22.389 kip.
Calculation basis
Use a centered, unstaggered grid with straight load and rupture paths. Assess other plausible paths, gusset stability, and fastener resistance separately.
Hole and tension areas
For inch-series standard holes, the net deduction is the nominal J3.3 hole diameter plus 1/16 in per B4.3. This is dᵦ + 1/8 in through 7/8-in bolts and dᵦ + 3/16 in for 1-in and larger bolts. Aₑ = UAₙ. D2 compares FᵧAᵍ and FᵤAₑ with their separate design factors.
Block path geometry
The U path runs along both outside bolt lines and across the last row. The edge path runs along one outside bolt line and across the nearest side ligament. Each shear plane deducts n − ½ enlarged holes. The tension path counts half a hole at each intersected end plus whole interior holes.
J4.3 rupture
Rₙ = min(0.60FᵤAₙᵥ, 0.60FᵧAᵍᵥ) + UᵦₛFᵤAₙₜ. Use Uᵦₛ = 1.0 for uniform tension stress or 0.5 for nonuniform stress. Apply φ = 0.75 or Ω = 2.00.