SteelBeamLab

Centered wide-flange base on a concrete pier

Use a square plate and centered concentric compression. Compare plate yield-line thickness with the trial plate.

Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.

ANSI/AISC 360-22J8 · DG 1
Design method
Units

Inputs

LRFD

Use loads and strengths from the selected method. Re-enter values after switching methods.

Column & load
Steel plate
Concrete pedestal

Base plate plan

Within modeled limits
Bearing P
1,034.28kip
Bearing area
58.824in²
Min. plate t
0.917in
Gov. length
4.12in
Base plate planThe dashed rectangle is the 0.95d × 0.80b_f effective column footprint used to measure m and n.Pedestal & plateCentered compressionNBm 2.968 inn 4.12 inλn′ 1.673 inLRFD · Plate thickness91.7%0%100% limit140%+
The dashed rectangle is the 0.95d × 0.80b_f effective column footprint used to measure m and n.

Calculation results

Limit stateDemandAvailableUse
Concrete bearing260 kip1,034.28 kip25.1%
Plate thickness0.917 in1 in91.7%

Calculation values

Plate area A₁
324 in²
Similar support area A₂
676 in²
Confinement multiplier
1.444
Applied bearing pressure
0.802 ksi
Projection m
2.968 in
Projection n
4.12 in
Inner projection n′
3.112 in
Yield-line factor λ
0.537
Effective inner λn′
1.673 in
Nominal concrete bearing
1,591.2 kip
Available bearing · LRFD
1,034.28 kip
Available bearing · ASD
688.831 kip

Worked solution at the starting values

  1. Use bearing area 324 in² and confinement multiplier 1.444.
  2. Compare m = 2.968 in, n = 4.12 in, and λn′ = 1.673 in.
  3. Use the governing projection to calculate the minimum plate thickness of 0.917 in.

Calculation basis

For an I-shaped column in centered full-contact compression on a rectangular pedestal. Check the governing concrete code, anchors, grout, welds, and any eccentric load separately.

Concrete confinement

J8 uses 0.85f′cA₁ times the lesser of 2 and √(A₂/A₁). Here A₂ is the largest centered rectangle similar to the plate that fits on the pedestal. Use φc = 0.65 or Ωc = 2.31. The required bearing-only area holds the plate aspect ratio and pedestal fixed.

Plate projection

DG 1 uses m = (N − 0.95d)/2, n = (B − 0.80b_f)/2, and n′ = √(db_f)/4. With X = [4db_f/(d + b_f)²](Pᵣ/available concrete bearing), λ = 2√X/(1 + √(1 − X)), capped at one. The governing projection is the largest of m, n, and λn′.

Thickness

Use tₘᵢₙ = ℓ√[2Pᵣ/(FᵧBN·factor)]. The factor is 0.90 for LRFD and 1/1.67 for ASD. Compare the theoretical minimum to the selected plate thickness and check the concrete bearing separately.

References and units ↗

More worked examples