Set all four moment ordinates equal. The quarter-point expression gives Cᵦ = 1.0 and highlights the effect of lower yield stress on the transitions.
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
ANSI/AISC 360-22F1 · F2
Inputs
LRFD
Use loads and strengths from the selected method. Re-enter values after switching methods.
LTB strength curve
Within modeled limits
Yield limit Lₚ
5.079ft
LTB limit Lᵣ
15.049ft
Nominal Mₙ
129.221kip-ft
Cᵦ factor
1
The point marks the entered Lᵦ. Colored bands separate yielding, inelastic LTB, and elastic LTB. The curve is capped at Mₚ.
Calculation results
Limit state
Demand
Available
Use
Major-axis bending
115 kip-ft
116.299 kip-ft
98.9%
Calculation values
Bracing zone
Inelastic LTB
Plastic moment Mₚ
199.5 kip-ft
Elastic Fcr
—
Available bending · LRFD
116.299 kip-ft
Available bending · ASD
77.378 kip-ft
SteelBeamLab / AISC 360-22 F1 · F2
A36 member under uniform moment
LRFD · US customary
For compact, doubly symmetric I-sections with restrained ends at the braced segment. Classify the flange and web per Table B4.1b before selecting Compact. Verify brace stiffness, load height, and the moment diagram.
Entered values
Unbraced length Lᵦ
14 ft
Required moment Mᵣ
115 kip-ft
Flange and web class
Both compact
Steel yield stress Fᵧ
36 ksi
Elastic modulus Sₓ
57.6 in³
Plastic modulus Zₓ
66.5 in³
Minor-axis radius rᵧ
1.22 in
Effective radius rₜₛ
1.514 in
Torsion constant J
0.506 in⁴
Flange centroid spacing h₀
17.275 in
Cᵦ input method
Quarter-point moments
Peak moment Mmax
115 kip-ft
Quarter point Mᴀ
115 kip-ft
Midpoint Mʙ
115 kip-ft
Three-quarter point Mᴄ
115 kip-ft
Key results
Yield limit Lₚ
5.079ft
LTB limit Lᵣ
15.049ft
Nominal Mₙ
129.221kip-ft
Cᵦ factor
1
Limit-state screening
Limit state
Demand
Available
Use
Major-axis bending
115 kip-ft
116.299 kip-ft
98.9%
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
Worked solution at the starting values
Use Cᵦ = 1 from the chosen input method.
Calculate Lₚ = 5.079 ft and Lᵣ = 15.049 ft. The entered length is in Zone 2.
Calculate nominal bending strength 129.221 kip-ft and apply the selected design factor to obtain 116.299 kip-ft.
Calculation basis
For compact, doubly symmetric I-sections with restrained ends at the braced segment. Classify the flange and web per Table B4.1b before selecting Compact. Verify brace stiffness, load height, and the moment diagram.
Moment gradient
F1-1 gives Cᵦ = 12.5Mmax/(2.5Mmax + 3Mᴀ + 4Mʙ + 3Mᴄ). Use absolute moments within the same braced segment. An all-zero moment diagram uses Cᵦ = 1.0.
Zone transitions
F2-5 and F2-6 set Lₚ and Lᵣ using rᵧ, rₜₛ, J, Sₓ, h₀, Fᵧ, and E. For doubly symmetric I-sections, c = 1. Supply rₜₛ from the section table or calculate rₜₛ = √(√(IᵧCw)/Sₓ).
Bending strength
F2-1 applies plastic yielding at Lᵦ ≤ Lₚ. F2-2 interpolates between Mₚ and 0.7FᵧSₓ, with Cᵦ and the cap at Mₚ. Beyond Lᵣ, F2-3 and F2-4 use the elastic LTB stress times Sₓ with the same cap.