Calculate major-axis demand, web shear capacity, and elastic deflection for a single span under a uniform load and a point load.
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
ANSI/AISC 360-22F2 · F7 · G2 · G4
Inputs
LRFD
Use loads and strengths from the selected method. Re-enter values after switching methods.
Span response
Within modeled limits
Peak moment
216kip-ft
Peak shear
30kip
Total deflect.
0.959in
Available M
249.375kip-ft
Shear and moment use strength loads. The deflected shape uses total service load. Diagram ordinates are independently scaled.
Calculation results
Limit state
Demand
Available
Use
Flexural yielding
216 kip-ft
249.375 kip-ft
86.6%
Web shear
30 kip
159.3 kip
18.8%
Live deflection
0.681 in
0.8 in
85.2%
Total deflection
0.959 in
1.2 in
79.9%
Calculation values
Left reaction
30 kip
Right reaction
30 kip
Left end moment
0 kip-ft
Live deflection
0.681 in
Plastic moment Mₚ
277.083 kip-ft
First-yield moment Mᵧ
240 kip-ft
Nominal shear Vₙ
159.3 kip
Shear area Aᵥ
5.31 in²
h/tw
53.5
Shear coefficient Cᵥ
1
Section inertia Iₓ
510 in⁴
Section yield stress Fᵧ
50 ksi
Flexural compactness
Compact
Available shear · LRFD
159.3 kip
Available shear · ASD
106.2 kip
Available bending · LRFD
249.375 kip-ft
Available bending · ASD
165.918 kip-ft
SteelBeamLab / AISC 360-22 F2 · F7 · G2 · G4
Steel Beam Bending, Shear & Deflection
LRFD · US customary
Use a compact, doubly symmetric section with adequate lateral restraint. Check bracing, local loads, load combinations, and project deflection criteria separately.
Entered values
Support condition
Simply supported
Span L
24 ft
Section preset
W18×35
Yield stress Fᵧ
50 ksi
Uniform load w
2 kip/ft
Point load P
12 kip
Point location from left
50 %
Dead uniform load
0.55 kip/ft
Live uniform load
0.85 kip/ft
Dead point load
0 kip
Live point load
7.5 kip
Key results
Peak moment
216kip-ft
Peak shear
30kip
Total deflect.
0.959in
Available M
249.375kip-ft
Limit-state screening
Limit state
Demand
Available
Use
Flexural yielding
216 kip-ft
249.375 kip-ft
86.6%
Web shear
30 kip
159.3 kip
18.8%
Live deflection
0.681 in
0.8 in
85.2%
Total deflection
0.959 in
1.2 in
79.9%
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
Calculation basis
Use a compact, doubly symmetric section with adequate lateral restraint. Check bracing, local loads, load combinations, and project deflection criteria separately.
Span response
Solve beam equilibrium and integrate M/EI over the span. For fixed–pinned support, the right reaction enforces zero vertical movement at the pin. Demand uses the absolute peaks, including the fixed-end region and both sides of the point load.
Flexure and shear
The plastic yielding ceiling is Mₚ = FᵧZₓ. Available bending strength is 0.90Mₚ or Mₚ/1.67 when compactness is satisfied. Web shear is 0.6FᵧAᵥCᵥ. G2 uses Aᵥ = dtw and G4 uses the two clear HSS webs. Rolled I-shapes below the G2.1(a) threshold get φᵥ = 1.00 and Ωᵥ = 1.50. Other supported cases use 0.90 and 1.67.
Serviceability
Enter downward dead and live service loads separately. Include self-weight in the dead case when applicable. Live deflection is checked against L/360 and dead plus live against L/240; project criteria may differ. The model uses linear elastic flexure and neglects shear deformation.