Use a 16 ft roof span with uniform load only. This case makes the wL²/8 moment and 5wL⁴/(384EI) deflection easy to verify.
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
ANSI/AISC 360-22F2 · F7 · G2 · G4
Inputs
LRFD
Use loads and strengths from the selected method. Re-enter values after switching methods.
Span response
Within modeled limits
Peak moment
52.8kip-ft
Peak shear
13.2kip
Total deflect.
0.249in
Available M
139.5kip-ft
Shear and moment use strength loads. The deflected shape uses total service load. Diagram ordinates are independently scaled.
Calculation results
Limit state
Demand
Available
Use
Flexural yielding
52.8 kip-ft
139.5 kip-ft
37.8%
Web shear
13.2 kip
84.18 kip
15.7%
Live deflection
0.137 in
0.533 in
25.7%
Total deflection
0.249 in
0.8 in
31.2%
Calculation values
Left reaction
13.2 kip
Right reaction
13.2 kip
Left end moment
0 kip-ft
Live deflection
0.137 in
Plastic moment Mₚ
155 kip-ft
First-yield moment Mᵧ
139.167 kip-ft
Nominal shear Vₙ
84.18 kip
Shear area Aᵥ
2.806 in²
h/tw
47.2
Shear coefficient Cᵥ
1
Section inertia Iₓ
204 in⁴
Section yield stress Fᵧ
50 ksi
Flexural compactness
Compact
Available shear · LRFD
84.18 kip
Available shear · ASD
56.12 kip
Available bending · LRFD
139.5 kip-ft
Available bending · ASD
92.814 kip-ft
SteelBeamLab / AISC 360-22 F2 · F7 · G2 · G4
W12×26 roof beam with uniform load
LRFD · US customary
Use a compact, doubly symmetric section with adequate lateral restraint. Check bracing, local loads, load combinations, and project deflection criteria separately.
Entered values
Support condition
Simply supported
Span L
16 ft
Section preset
W12×26
Yield stress Fᵧ
50 ksi
Uniform load w
1.65 kip/ft
Point load P
0 kip
Point location from left
50 %
Dead uniform load
0.45 kip/ft
Live uniform load
0.55 kip/ft
Dead point load
0 kip
Live point load
0 kip
Key results
Peak moment
52.8kip-ft
Peak shear
13.2kip
Total deflect.
0.249in
Available M
139.5kip-ft
Limit-state screening
Limit state
Demand
Available
Use
Flexural yielding
52.8 kip-ft
139.5 kip-ft
37.8%
Web shear
13.2 kip
84.18 kip
15.7%
Live deflection
0.137 in
0.533 in
25.7%
Total deflection
0.249 in
0.8 in
31.2%
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
Worked solution at the starting values
Resolve the strength-load reactions. The left reaction is 13.2 kip and the right reaction is 13.2 kip.
Evaluate the peak absolute moment and shear. The demand is 52.8 kip-ft in bending and 13.2 kip in shear.
Integrate the service-load bending diagram with the selected Iₓ. Live deflection is 0.137 in and total deflection is 0.249 in.
Calculation basis
Use a compact, doubly symmetric section with adequate lateral restraint. Check bracing, local loads, load combinations, and project deflection criteria separately.
Span response
Solve beam equilibrium and integrate M/EI over the span. For fixed–pinned support, the right reaction enforces zero vertical movement at the pin. Demand uses the absolute peaks, including the fixed-end region and both sides of the point load.
Flexure and shear
The plastic yielding ceiling is Mₚ = FᵧZₓ. Available bending strength is 0.90Mₚ or Mₚ/1.67 when compactness is satisfied. Web shear is 0.6FᵧAᵥCᵥ. G2 uses Aᵥ = dtw and G4 uses the two clear HSS webs. Rolled I-shapes below the G2.1(a) threshold get φᵥ = 1.00 and Ωᵥ = 1.50. Other supported cases use 0.90 and 1.67.
Serviceability
Enter downward dead and live service loads separately. Include self-weight in the dead case when applicable. Live deflection is checked against L/360 and dead plus live against L/240; project criteria may differ. The model uses linear elastic flexure and neglects shear deformation.