Amplify the non-sway components using different elastic buckling loads. Both entered moments belong to the same combination.
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
ANSI/AISC 360-22H1-1 · App. 8
Inputs
LRFD
Use loads and strengths from the selected method. Re-enter values after switching methods.
Normalized P–M envelope
Within modeled limits
H1 unity
0.958
Axial ratio
0.391
Moment sum
0.638
Equation
H1-1a
The horizontal axis combines major- and minor-axis moment ratios. The envelope changes slope at Pᵣ/P_c = 0.20.
Calculation results
Limit state
Demand
Available
Use
Axial and biaxial bending
0.958
1
95.8%
Calculation values
Major-axis moment ratio
0.469
Minor-axis moment ratio
0.169
Major-axis Mᵣₓ
121.817 kip-ft
Minor-axis Mᵣᵧ
25.349 kip-ft
Load factor α
1
Major-axis B₁
1.194
Minor-axis B₁
1.334
SteelBeamLab / AISC 360-22 H1-1 · App. 8
Local B₁ magnification about two axes
LRFD · US customary
Provide available member strengths and governing concurrent demands from the same design method. Apply full project stability analysis, including sidesway as required.
Entered values
Moment input
Apply B₁ to non-sway
Compression Pᵣ
225 kip
Major-axis moment Mₓ
102 kip-ft
Minor-axis moment Mᵧ
19 kip-ft
Compression P_c
575 kip
Major moment M_cₓ
260 kip-ft
Minor moment M_cᵧ
150 kip-ft
Major-axis Cₘ
0.95
Minor-axis Cₘ
0.85
Major-axis Pₑ₁
1,100 kip
Minor-axis Pₑ₁
620 kip
Amplified sway Mₓ
0 kip-ft
Amplified sway Mᵧ
0 kip-ft
Key results
H1 unity
0.958
Axial ratio
0.391
Moment sum
0.638
Equation
H1-1a
Limit-state screening
Limit state
Demand
Available
Use
Axial and biaxial bending
0.958
1
95.8%
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
Worked solution at the starting values
Use B₁ factors 1.194 and 1.334 for the non-sway components.
Calculate Pᵣ/P_c = 0.391 and moment ratio sum 0.638. Apply H1-1a.
Compare unity 0.958 with the interaction limit of 1.0.
Calculation basis
Provide available member strengths and governing concurrent demands from the same design method. Apply full project stability analysis, including sidesway as required.
Higher axial ratio
At Pᵣ/P_c ≥ 0.20, apply the H1-1a equation Pᵣ/P_c + (8/9)(Mᵣₓ/M_cₓ + Mᵣᵧ/M_cᵧ) ≤ 1.0. Use absolute second-order moments.
Lower axial ratio
At Pᵣ/P_c < 0.20, apply the H1-1b equation Pᵣ/(2P_c) + Mᵣₓ/M_cₓ + Mᵣᵧ/M_cᵧ ≤ 1.0. The two branches meet at normalized moment sum 0.90.
Optional local P–δ
For each axis, B₁ = max[1, Cₘ/(1 − αPᵣ/Pₑ₁)] with α = 1.0 for LRFD or 1.6 for ASD. Enter Pₑ₁ from the applicable non-sway analysis stiffness and effective length. Add any separately amplified sway moment on the same sign convention.