Combine axial compression and bending about both principal axes. The axial ratio exceeds 0.20 and activates H1-1a.
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
ANSI/AISC 360-22H1-1 · App. 8
Inputs
LRFD
Use loads and strengths from the selected method. Re-enter values after switching methods.
Normalized P–M envelope
Within modeled limits
H1 unity
0.866
Axial ratio
0.348
Moment sum
0.583
Equation
H1-1a
The horizontal axis combines major- and minor-axis moment ratios. The envelope changes slope at Pᵣ/P_c = 0.20.
Calculation results
Limit state
Demand
Available
Use
Axial and biaxial bending
0.866
1
86.6%
Calculation values
Major-axis moment ratio
0.423
Minor-axis moment ratio
0.16
Major-axis Mᵣₓ
110 kip-ft
Minor-axis Mᵣᵧ
24 kip-ft
SteelBeamLab / AISC 360-22 H1-1 · App. 8
Beam-column on the higher-axial H1 branch
LRFD · US customary
Provide available member strengths and governing concurrent demands from the same design method. Apply full project stability analysis, including sidesway as required.
Entered values
Moment input
Second-order moments
Compression Pᵣ
200 kip
Major-axis moment Mₓ
110 kip-ft
Minor-axis moment Mᵧ
24 kip-ft
Compression P_c
575 kip
Major moment M_cₓ
260 kip-ft
Minor moment M_cᵧ
150 kip-ft
Key results
H1 unity
0.866
Axial ratio
0.348
Moment sum
0.583
Equation
H1-1a
Limit-state screening
Limit state
Demand
Available
Use
Axial and biaxial bending
0.866
1
86.6%
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
Worked solution at the starting values
Use the entered second-order moments.
Calculate Pᵣ/P_c = 0.348 and moment ratio sum 0.583. Apply H1-1a.
Compare unity 0.866 with the interaction limit of 1.0.
Calculation basis
Provide available member strengths and governing concurrent demands from the same design method. Apply full project stability analysis, including sidesway as required.
Higher axial ratio
At Pᵣ/P_c ≥ 0.20, apply the H1-1a equation Pᵣ/P_c + (8/9)(Mᵣₓ/M_cₓ + Mᵣᵧ/M_cᵧ) ≤ 1.0. Use absolute second-order moments.
Lower axial ratio
At Pᵣ/P_c < 0.20, apply the H1-1b equation Pᵣ/(2P_c) + Mᵣₓ/M_cₓ + Mᵣᵧ/M_cᵧ ≤ 1.0. The two branches meet at normalized moment sum 0.90.
Optional local P–δ
For each axis, B₁ = max[1, Cₘ/(1 − αPᵣ/Pₑ₁)] with α = 1.0 for LRFD or 1.6 for ASD. Enter Pₑ₁ from the applicable non-sway analysis stiffness and effective length. Add any separately amplified sway moment on the same sign convention.