SteelBeamLab

ASD braced column with unequal K factors

Set different K factors consistent with an idealized frame analysis. Compare allowable flexural-buckling strength with the ASD load.

Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.

ANSI/AISC 360-22E2 · E3
Design method
Units

Inputs

ASD

Use loads and strengths from the selected method. Re-enter values after switching methods.

Effective length
Section & compression

Column buckling curve

Within modeled limits
Governing KL/r
57.778
Crit. stress
39.171ksi
Available P
337.762kip
Buckling axis
Y
Column buckling curveThe dot follows the governing KL/r. The E3 branch changes at 4.71√(E/Fᵧ). The preferred slenderness limit is shown at 200.06012.51202518037.524050Fcr (ksi)KL/rInelasticElastic200 screenASD · Flexural buckling72.54%0%100% limit140%+
The dot follows the governing KL/r. The E3 branch changes at 4.71√(E/Fᵧ). The preferred slenderness limit is shown at 200.

Calculation results

Limit stateDemandAvailableUse
Flexural buckling245 kip337.762 kip72.5%

Calculation values

Major-axis KL/r
29.388
Minor-axis KL/r
57.778
E3 branch
Inelastic
Branch transition
113.432
Euler stress Fₑ
85.739 ksi
Nominal strength Pₙ
564.063 kip
Available compression · LRFD
507.657 kip
Available compression · ASD
337.762 kip

Worked solution at the starting values

  1. Compute KL/r about each axis. The major-axis ratio is 29.388 and the minor-axis ratio is 57.778.
  2. Apply the inelastic E3 branch to obtain Fcr = 39.171 ksi.
  3. Multiply the critical stress by gross area and apply the design factor. Available compression is 337.762 kip.

Calculation basis

Use nonslender sections. Verify local, torsional and flexural-torsional buckling, frame stability, and effective lengths separately.

Effective slenderness

For each principal axis, divide effective length KL by radius of gyration r. The larger ratio controls the flexural buckling stress. E2 recommends limiting KL/r to 200 for members designed for compression.

E3 critical stress

Fₑ = π²E/(KL/r)². At KL/r ≤ 4.71√(E/Fᵧ), Fcr = 0.658^(Fᵧ/Fₑ)Fᵧ. Beyond that transition, Fcr = 0.877Fₑ. AISC 360-22 denotes this nominal stress Fₙ.

Available compression

Multiply Fcr by gross area Aᵍ for Pₙ. Available strength is 0.90Pₙ for LRFD or Pₙ/1.67 for ASD. Supply K values from the applicable stability method.

References and units ↗

More worked examples