Provide intermediate bracing along the minor direction. The longer effective length makes the major axis govern despite its larger radius.
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
ANSI/AISC 360-22E2 · E3
Inputs
LRFD
Use loads and strengths from the selected method. Re-enter values after switching methods.
Column buckling curve
Within modeled limits
Governing KL/r
62.738
Crit. stress
37.496ksi
Available P
593.936kip
Buckling axis
X
The dot follows the governing KL/r. The E3 branch changes at 4.71√(E/Fᵧ). The preferred slenderness limit is shown at 200.
Calculation results
Limit state
Demand
Available
Use
Flexural buckling
320 kip
593.936 kip
53.9%
Calculation values
Major-axis KL/r
62.738
Minor-axis KL/r
28.79
E3 branch
Inelastic
Branch transition
113.432
Euler stress Fₑ
72.718 ksi
Nominal strength Pₙ
659.928 kip
Available compression · LRFD
593.936 kip
Available compression · ASD
395.167 kip
SteelBeamLab / AISC 360-22 E2 · E3
Column with a longer major-axis unbraced length
LRFD · US customary
Use nonslender sections. Verify local, torsional and flexural-torsional buckling, frame stability, and effective lengths separately.
Entered values
Unbraced length Lₓ
25 ft
Unbraced length Lᵧ
7 ft
Length factor Kₓ
1.1
Length factor Kᵧ
0.85
Gross area Aᵍ
17.6 in²
Major-axis radius rₓ
5.26 in
Minor-axis radius rᵧ
2.48 in
Steel yield stress Fᵧ
50 ksi
Required compression Pᵣ
320 kip
Key results
Governing KL/r
62.738
Crit. stress
37.496ksi
Available P
593.936kip
Buckling axis
X
Limit-state screening
Limit state
Demand
Available
Use
Flexural buckling
320 kip
593.936 kip
53.9%
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
Worked solution at the starting values
Compute KL/r about each axis. The major-axis ratio is 62.738 and the minor-axis ratio is 28.79.
Apply the inelastic E3 branch to obtain Fcr = 37.496 ksi.
Multiply the critical stress by gross area and apply the design factor. Available compression is 593.936 kip.
Calculation basis
Use nonslender sections. Verify local, torsional and flexural-torsional buckling, frame stability, and effective lengths separately.
Effective slenderness
For each principal axis, divide effective length KL by radius of gyration r. The larger ratio controls the flexural buckling stress. E2 recommends limiting KL/r to 200 for members designed for compression.
E3 critical stress
Fₑ = π²E/(KL/r)². At KL/r ≤ 4.71√(E/Fᵧ), Fcr = 0.658^(Fᵧ/Fₑ)Fᵧ. Beyond that transition, Fcr = 0.877Fₑ. AISC 360-22 denotes this nominal stress Fₙ.
Available compression
Multiply Fcr by gross area Aᵍ for Pₙ. Available strength is 0.90Pₙ for LRFD or Pₙ/1.67 for ASD. Supply K values from the applicable stability method.