Add concurrent bolt tension to a four-bolt Class A joint. Check how the reduced clamping force changes slip resistance.
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
ANSI/AISC 360-22J3
Inputs
LRFD
Use loads and strengths from the selected method. Re-enter values after switching methods.
Bolt group and cutaway
Limit exceeded
Bolt shear
71.569kip
Bolt tension
100.067kip
Plate limit
95.977kip
Slip resist.
30.168kip
The plan shows the loaded end and governing clear distance. The cutaway shows the chosen shear planes through the connected plies.
Calculation results
Limit state
Demand
Available
Use
Bolt shear
33 kip
71.569 kip
46.1%
Bolt tension with shear
26 kip
100.067 kip
26%
Plate tearout
33 kip
95.977 kip
34.4%
Slip resistance
33 kip
30.168 kip
109.4%
Calculation values
Gross shank area Aᵦ
0.442 in²
Standard hole diameter
0.813 in
Fₙᵥ used
54 ksi
Applied bolt shear stress
18.674 ksi
Unmodified Fₙₜ
90 ksi
Modified F′ₙₜ
75.502 ksi
Clear distance at end
1.094 in
Clear distance at pitch
2.188 in
Nominal bearing per bolt
43.875 kip
Nominal tearout per bolt
31.992 kip
Bolt pretension Tᵦ
28 kip
Faying surface coefficient μ
0.3
Filler factor h_f
1
Clamping reduction k_sc
0.795
Group slip before factors
37.968 kip
SteelBeamLab / AISC 360-22 J3
Class A slip-critical joint under tension
LRFD · US customary
Use standard circular holes and equal direct force per bolt. Verify eccentricity, prying, fatigue, and each connected ply using full connection details.
Entered values
F3125 bolt grade
A325 · Group 120
Nominal bolt diameter
3/4 in
Threads at shear plane
N · Included
Shear planes per bolt
Single shear
Bolts in load line
4
Connection type
Slip-critical
Plate thickness t
0.375 in
Plate tensile stress Fᵤ
65 ksi
Loaded end distance
1.5 in
Bolt pitch
3 in
Service hole deformation
Consider deformation
Required shear Vᵣ
33 kip
Required tension Tᵣ
26 kip
Faying surface class
Class A · μ 0.30
Slip planes per bolt
One plane
Fillers
None or one
Key results
Bolt shear
71.569kip
Bolt tension
100.067kip
Plate limit
95.977kip
Slip resist.
30.168kip
Limit-state screening
Limit state
Demand
Available
Use
Bolt shear
33 kip
71.569 kip
46.1%
Bolt tension with shear
26 kip
100.067 kip
26%
Plate tearout
33 kip
95.977 kip
34.4%
Slip resistance
33 kip
30.168 kip
109.4%
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
Worked solution at the starting values
Convert the group shear to stress on the bolt shear planes. The applied stress is 18.674 ksi and the adjusted nominal tensile stress is 75.502 ksi.
Find the minimum clear distance 1.094 in and compare the nominal edge tearout and bearing strengths.
Compare the required bolt and plate forces with available strengths. Slip resistance governs at 109.4% utilization.
Calculation basis
Use standard circular holes and equal direct force per bolt. Verify eccentricity, prying, fatigue, and each connected ply using full connection details.
Bolt rupture and interaction
Use J3.2 nominal bolt stresses with the gross shank area and the number of shear planes. J3.8 reduces Fₙₜ to F′ₙₜ as shear stress rises. The tensile capacity uses one gross shank area per bolt. For an end-loaded pattern over 38 in, reduce Fₙᵥ to 83.3%.
Bearing and tearout
J3.11a limits each bolt to min(2.4dtFᵤ, 1.2l꜀tFᵤ) when service-load hole deformation matters, and min(3.0dtFᵤ, 1.5l꜀tFᵤ) when it does not. One bolt is at the loaded end and the rest are spaced at the entered pitch. The equal-load group uses the weakest position times bolt count.
Slip-critical option
J3.9 uses μDᵤh_fTᵦnₛ per bolt. J3.10 applies the clamping reduction kₛ꜀ due to group tension. Standard holes use φ = 1.00 or Ω = 1.50 for slip. Slip-critical joints also receive the bolt rupture and plate checks.