SteelBeamLab

Thin end plate governed by tearout

Keep the standard hole close to the loaded edge. Compare the tearout expression against the upper bearing strength.

Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.

ANSI/AISC 360-22J3
Design method
Units

Inputs

LRFD

Use loads and strengths from the selected method. Re-enter values after switching methods.

Bolt group
Inch-series F3125 bolt sizes. SI displays their converted dimensions.
Connected plate
Group forces

Bolt group and cutaway

Limit exceeded
Bolt shear
53.677kip
Bolt tension
64.634kip
Plate limit
26.928kip
Clear dist.
0.614in
Bolt group and cutawayThe plan shows the loaded end and governing clear distance. The cutaway shows the chosen shear planes through the connected plies.Plate planl_c = 0.6138 inCutawaySingle sheart = 0.25 inLRFD · Plate tearout115.1%0%100% limit140%+
The plan shows the loaded end and governing clear distance. The cutaway shows the chosen shear planes through the connected plies.

Calculation results

Limit stateDemandAvailableUse
Bolt shear31 kip53.677 kip57.8%
Bolt tension with shear1 kip64.634 kip1.5%
Plate tearout31 kip26.928 kip115.1%

Calculation values

Gross shank area Aᵦ
0.442 in²
Standard hole diameter
0.813 in
Fₙᵥ used
54 ksi
Applied bolt shear stress
23.39 ksi
Unmodified Fₙₜ
90 ksi
Modified F′ₙₜ
65.022 ksi
Clear distance at end
0.614 in
Clear distance at pitch
1.688 in
Nominal bearing per bolt
29.25 kip
Nominal tearout per bolt
11.968 kip

Worked solution at the starting values

  1. Convert the group shear to stress on the bolt shear planes. The applied stress is 23.39 ksi and the adjusted nominal tensile stress is 65.022 ksi.
  2. Find the minimum clear distance 0.614 in and compare the nominal edge tearout and bearing strengths.
  3. Compare the required bolt and plate forces with available strengths. Plate tearout governs at 115.1% utilization.

Calculation basis

Use standard circular holes and equal direct force per bolt. Verify eccentricity, prying, fatigue, and each connected ply using full connection details.

Bolt rupture and interaction

Use J3.2 nominal bolt stresses with the gross shank area and the number of shear planes. J3.8 reduces Fₙₜ to F′ₙₜ as shear stress rises. The tensile capacity uses one gross shank area per bolt. For an end-loaded pattern over 38 in, reduce Fₙᵥ to 83.3%.

Bearing and tearout

J3.11a limits each bolt to min(2.4dtFᵤ, 1.2l꜀tFᵤ) when service-load hole deformation matters, and min(3.0dtFᵤ, 1.5l꜀tFᵤ) when it does not. One bolt is at the loaded end and the rest are spaced at the entered pitch. The equal-load group uses the weakest position times bolt count.

Slip-critical option

J3.9 uses μDᵤh_fTᵦnₛ per bolt. J3.10 applies the clamping reduction kₛ꜀ due to group tension. Standard holes use φ = 1.00 or Ω = 1.50 for slip. Slip-critical joints also receive the bolt rupture and plate checks.

References and units ↗

More worked examples