SteelBeamLab

Long end-loaded A325 bolt pattern

Extend one line of bolts past 38 in between the first and last centers. Compare reduced shear stress capacity with the unmodified tabular value.

Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.

ANSI/AISC 360-22J3
Design method
Units

Inputs

LRFD

Use loads and strengths from the selected method. Re-enter values after switching methods.

Bolt group
Inch-series F3125 bolt sizes. SI displays their converted dimensions.
Connected plate
Group forces

Bolt group and cutaway

Within modeled limits
Bolt shear
208.661kip
Bolt tension
138.573kip
Plate limit
825.398kip
Clear dist.
1.344in
Bolt group and cutawayThe plan shows the loaded end and governing clear distance. The cutaway shows the chosen shear planes through the connected plies.Plate planl_c = 1.344 inCutawaySingle sheart = 0.75 inLRFD · Bolt shear96.81%0%100% limit140%+
The plan shows the loaded end and governing clear distance. The cutaway shows the chosen shear planes through the connected plies.

Calculation results

Limit stateDemandAvailableUse
Bolt shear202 kip208.661 kip96.8%
Bolt tension with shear31 kip138.573 kip22.4%
Plate tearout202 kip825.398 kip24.5%
  • The end-loaded bolt pattern exceeds 38 in. Fₙᵥ is reduced to 83.3% of its tabulated value.

Calculation values

Gross shank area Aᵦ
0.442 in²
Standard hole diameter
0.813 in
Fₙᵥ used
44.982 ksi
Applied bolt shear stress
32.66 ksi
Unmodified Fₙₜ
90 ksi
Modified F′ₙₜ
29.873 ksi
Clear distance at end
1.344 in
Clear distance at pitch
2.438 in
Nominal bearing per bolt
87.75 kip
Nominal tearout per bolt
78.609 kip

Worked solution at the starting values

  1. Convert the group shear to stress on the bolt shear planes. The applied stress is 32.66 ksi and the adjusted nominal tensile stress is 29.873 ksi.
  2. Find the minimum clear distance 1.344 in and compare the nominal edge tearout and bearing strengths.
  3. Compare the required bolt and plate forces with available strengths. Bolt shear governs at 96.8% utilization.

Calculation basis

Use standard circular holes and equal direct force per bolt. Verify eccentricity, prying, fatigue, and each connected ply using full connection details.

Bolt rupture and interaction

Use J3.2 nominal bolt stresses with the gross shank area and the number of shear planes. J3.8 reduces Fₙₜ to F′ₙₜ as shear stress rises. The tensile capacity uses one gross shank area per bolt. For an end-loaded pattern over 38 in, reduce Fₙᵥ to 83.3%.

Bearing and tearout

J3.11a limits each bolt to min(2.4dtFᵤ, 1.2l꜀tFᵤ) when service-load hole deformation matters, and min(3.0dtFᵤ, 1.5l꜀tFᵤ) when it does not. One bolt is at the loaded end and the rest are spaced at the entered pitch. The equal-load group uses the weakest position times bolt count.

Slip-critical option

J3.9 uses μDᵤh_fTᵦnₛ per bolt. J3.10 applies the clamping reduction kₛ꜀ due to group tension. Standard holes use φ = 1.00 or Ω = 1.50 for slip. Slip-critical joints also receive the bolt rupture and plate checks.

References and units ↗

More worked examples