Worked example · Controls & protection
Single concrete pipe under a local road
A circular concrete pipe with a square-edged headwall carries flow beneath a local roadway with shallow tailwater.
Inputs
Roadway culvert profile
Live resultsHeadwater below both limits
Inlet control. Overtopping uses the actual road crest. HW/D has a separate 1.2 worksheet limit.
Calculation results
- HW / D
- 0.93
- Inlet HW
- 2.79 ft
- Outlet HW
- 2.26 ft
- Road clearance
- 1.31 ft
- Governing control
- Inlet
- Inlet condition
- Unsubmerged
- Governing headwater depth
- 2.79 ft
- Headwater elevation
- 389.79 ft
- Road crest elevation
- 391.1 ft
- Reserve to HW/D 1.2
- 0.81 ft
- Critical depth
- 1.84 ft
- Barrel friction loss
- 0.12 ft
- Entrance + exit loss
- 0.48 ft
- Full-area barrel velocity
- 4.53 ft/s
Worked calculation
Compare headwater elevation with road elevation. The 1.2 depth ratio can be more restrictive than actual crest clearance.
HWin from Appendix A · HWout = h₀ + hfriction + (kₑ + 1)V²/(2g) − LS · HW = max(HWin, HWout).
The inlet calculation uses HDS-5 Table A.1. A linear blend between the published branch endpoints is used near inlet submergence. The outlet is a full-barrel energy screen with h₀ = max(TW, (d꜀ + D)/2), capped at D for the starting depth proxy before taking the maximum with tailwater. For outlet headwater below 0.75D, verify with a backwater calculation. The 1.2 ratio is a worksheet criterion. Road overtopping uses the surveyed road crest.
More worked examples
Open the main calculatorSingle concrete pipe under a local road
Inputs
- Total design flow
- 32 cfs
- Inlet configuration
- Round RCP · headwall
- Diameter or inside rise
- 3 ft
- Identical barrels
- 1
- Barrel length
- 54 ft
- Longitudinal grade
- 1.4 %
- Manning n
- 0.013
- Entrance loss kₑ
- 0.5
- Depth above outlet invert
- 0.85 ft
- Inlet invert elevation
- 387 ft
- Road crest above inlet invert
- 4.1 ft
Results
- HW / D
- 0.93
- Inlet HW
- 2.79 ft
- Outlet HW
- 2.26 ft
- Road clearance
- 1.31 ft
- Governing control
- Inlet
- Inlet condition
- Unsubmerged
- Governing headwater depth
- 2.79 ft
- Headwater elevation
- 389.79 ft
- Road crest elevation
- 391.1 ft
- Reserve to HW/D 1.2
- 0.81 ft
- Critical depth
- 1.84 ft
- Barrel friction loss
- 0.12 ft
- Entrance + exit loss
- 0.48 ft
- Full-area barrel velocity
- 4.53 ft/s
Headwater below both limits
Inlet control. Overtopping uses the actual road crest. HW/D has a separate 1.2 worksheet limit.
HWin from Appendix A · HWout = h₀ + hfriction + (kₑ + 1)V²/(2g) − LS · HW = max(HWin, HWout).