Worked example · Controls & protection
Thin-wall projecting culvert inlet
A projecting corrugated pipe at a small road crossing uses a high entrance-loss coefficient and a short barrel.
Inputs
Roadway culvert profile
Live resultsHeadwater below both limits
Inlet control. Overtopping uses the actual road crest. HW/D has a separate 1.2 worksheet limit.
Calculation results
- HW / D
- 1.09
- Inlet HW
- 3.83 ft
- Outlet HW
- 3.1 ft
- Road clearance
- 0.77 ft
- Governing control
- Inlet
- Inlet condition
- Unsubmerged
- Governing headwater depth
- 3.83 ft
- Headwater elevation
- 103.83 ft
- Road crest elevation
- 104.6 ft
- Reserve to HW/D 1.2
- 0.37 ft
- Critical depth
- 2.28 ft
- Barrel friction loss
- 0.42 ft
- Entrance + exit loss
- 0.9 ft
- Full-area barrel velocity
- 5.51 ft/s
Worked calculation
Compare the projecting preset with a headwall and review the different inlet and outlet results.
HWin from Appendix A · HWout = h₀ + hfriction + (kₑ + 1)V²/(2g) − LS · HW = max(HWin, HWout).
The inlet calculation uses HDS-5 Table A.1. A linear blend between the published branch endpoints is used near inlet submergence. The outlet is a full-barrel energy screen with h₀ = max(TW, (d꜀ + D)/2), capped at D for the starting depth proxy before taking the maximum with tailwater. For outlet headwater below 0.75D, verify with a backwater calculation. The 1.2 ratio is a worksheet criterion. Road overtopping uses the surveyed road crest.
More worked examples
Open the main calculatorThin-wall projecting culvert inlet
Inputs
- Total design flow
- 53 cfs
- Inlet configuration
- Round CMP · projecting
- Diameter or inside rise
- 3.5 ft
- Identical barrels
- 1
- Barrel length
- 44 ft
- Longitudinal grade
- 2.5 %
- Manning n
- 0.024
- Entrance loss kₑ
- 0.9
- Depth above outlet invert
- 1.5 ft
- Inlet invert elevation
- 100 ft
- Road crest above inlet invert
- 4.6 ft
Results
- HW / D
- 1.09
- Inlet HW
- 3.83 ft
- Outlet HW
- 3.1 ft
- Road clearance
- 0.77 ft
- Governing control
- Inlet
- Inlet condition
- Unsubmerged
- Governing headwater depth
- 3.83 ft
- Headwater elevation
- 103.83 ft
- Road crest elevation
- 104.6 ft
- Reserve to HW/D 1.2
- 0.37 ft
- Critical depth
- 2.28 ft
- Barrel friction loss
- 0.42 ft
- Entrance + exit loss
- 0.9 ft
- Full-area barrel velocity
- 5.51 ft/s
Headwater below both limits
Inlet control. Overtopping uses the actual road crest. HW/D has a separate 1.2 worksheet limit.
HWin from Appendix A · HWout = h₀ + hfriction + (kₑ + 1)V²/(2g) − LS · HW = max(HWin, HWout).
Screening worksheet · Verify design using project criteria and site data.