Denver, Colorado
A south eave for a Denver passive house
A retrofit adds a two-foot eave above a five-foot south window. The underside is six feet above the sill.
Try it. Set depth to the reported full-shade depth. Compare summer noon shade and winter glass admission before picking a standard projection.
Inputs used
Window and eave cross-section
Results paused. Check the highlighted inputs.
- Summer full-shade depth
- 1.75 ft
- Winter direct sun
- 99.8%
- Summer window shade
- 100%
- Gap above the glass
- 1 ft
- March equinox shade
- 28%
- September equinox shade
- 27.8%
The full-shade depth covers the glass at summer solar noon. Shadow moves across the glass during the day.
| Season | Date | Profile angle | Glass in direct sun |
|---|---|---|---|
| Summer solstice | 2026-06-21 | 73.7° | 0% |
| Winter solstice | 2026-12-21 | 26.8° | 99.8% |
| March equinox | 2026-03-20 | 50.2° | 72% |
| September equinox | 2026-09-23 | 50.1° | 72.2% |
The wall sees a profile angle
An oblique ray looks steeper in a vertical section perpendicular to the wall. The calculator projects the horizontal component of that ray onto the wall’s outward normal, then divides the vertical component by that projection.
The eave shades a vertical distance equal to its depth times the tangent of the profile angle. At the summer solstice, the full-shade depth is the sill-to-eave height divided by that tangent at solar noon. The model assumes a level eave of unlimited width.
Common questions
How much clear wall sits above the Denver window?
The sill-to-eave measurement is six feet and the window is five feet high, leaving one foot above the glass.
Can a Denver summer-depth target still admit winter sun?
The winter solar profile is shallower. Its shadow usually reaches less distance down the glass for the same eave.