Bushing bore comparator
AIAG MSA · 4th edition / SI units
- GRR sigma
- 1.037791 µm
- GRR study var
- 7.9105 %
- GRR tolerance
- 6.2267 %
- Distinct groups
- 17
Inputs
- Input mode
- Raw crossed study
- Verdict basis
- % study variation
- Appraisers
- 3
- Trials per part
- 3
- Parts
- 8
- LSL
- 21.95 mm
- USL
- 22.05 mm
Raw readings (mm), grouped by appraiser
- Part 1
- 21.9736 / 21.9741 / 21.9746 · 21.9755 / 21.97425 / 21.97475 · 21.97565 / 21.97615 / 21.9749
- Part 2
- 21.9791 / 21.97985 / 21.9806 · 21.981 / 21.98 / 21.98075 · 21.98115 / 21.9819 / 21.9809
- Part 3
- 21.9846 / 21.9856 / 21.9866 · 21.9865 / 21.98575 / 21.98675 · 21.98665 / 21.98765 / 21.9869
- Part 4
- 21.9901 / 21.9906 / 21.9911 · 21.992 / 21.99075 / 21.99125 · 21.99215 / 21.99265 / 21.9914
- Part 5
- 21.9956 / 21.99635 / 21.9971 · 21.9975 / 21.9965 / 21.99725 · 21.99765 / 21.9984 / 21.9974
- Part 6
- 22.0011 / 22.0021 / 22.0031 · 22.003 / 22.00225 / 22.00325 · 22.00315 / 22.00415 / 22.0034
- Part 7
- 22.0066 / 22.0071 / 22.0076 · 22.0085 / 22.00725 / 22.00775 · 22.00865 / 22.00915 / 22.0079
- Part 8
- 22.0121 / 22.01285 / 22.0136 · 22.014 / 22.013 / 22.01375 · 22.01415 / 22.0149 / 22.0139
Measurement system components
| Component | Sigma | Study var. | Contribution | Tolerance |
|---|---|---|---|---|
| EV | 0.7138833 µm | 5.4415 % | 0.2961 % | 4.2833 % |
| AV | 0.7532475 µm | 5.7415 % | 0.32965 % | 4.5195 % |
| GRR | 1.037791 µm | 7.9105 % | 0.62575 % | 6.2267 % |
| PV | 13.07813 µm | 99.687 % | 99.374 % | 78.469 % |
| TV | 13.11924 µm | 100 % | 100 % | 78.715 % |
Range checks
| Check | Result |
|---|---|
| R̄̄ · average repeat range | 1.208333 µm |
| X̄diff · appraiser mean range | 1.466667 µm |
| Rp · part mean range | 38.75 µm |
| K₁ / K₂ / K₃ | 0.5908 / 0.5231 / 0.3375 |
| ndc ≥ 5 | Met |
| R upper control limit | 3.11025 µm |
| X̄ control interval | 21.99307 mm to 21.99554 mm |
| R above UCL | 0 / 24 |
| X̄ outside control limits | 24 / 24 |
Verdict based on % study variation. ndc meets the screening goal. Use representative parts and blinded, randomized repeats. The method does not estimate appraiser × part interaction. A zero observed GRR gives no finite reliability estimate for ndc.