Large mold plate expansion
JCGM 100 / ASME B89.7.3.1 / SI units
- Combined uᶜ
- 8.251225 µm
- Expanded U
- 16.50245 µm
- Coverage k
- 2
- TUR
- 3.02985
Inputs
- Measured result
- 799.976 mm
- Reference length
- 800 mm
- Lower specification
- 799.95 mm
- Upper specification
- 800.05 mm
- Decision rule
- Guard band · ±U
- Coverage factor
- Fixed k = 2
- Repeatability SD
- 2.2 µm
- Repeat count
- 8
- Instrument input
- Expanded certificate uncertainty
- Instrument uncertainty / MPE
- 3.6 µm
- Certificate k
- 2
- Instrument df (optional)
- —
- Resolution increment
- 1 µm
- Probe / form half-width
- 1.4 µm
- Fixture / alignment half-width
- 1.1 µm
- Workpiece temperature
- 26 °C
- Estimated differential CTE
- 5 ppm/°C
- Differential CTE uncertainty
- 2.8 ppm/°C
- Temperature uncertainty
- 0.7 °C
- Thermal input distributions
- Rectangular half-widths
- Apply nominal thermal correction
- Yes
Uncertainty budget
| Component | Standard u | Degrees of freedom | Variance share |
|---|---|---|---|
| Repeatability | 0.7778175 µm | 7 | 0.88862 % |
| Instrument | 1.8 µm | ∞ | 4.7589 % |
| Resolution | 0.2886751 µm | ∞ | 0.1224 % |
| Probe / form | 0.8082904 µm | ∞ | 0.95962 % |
| Fixture / alignment | 0.6350853 µm | ∞ | 0.59242 % |
| Thermal mismatch | 7.943407 µm | ∞ | 92.678 % |
Conformance and coverage
| Check | Result |
|---|---|
| Measured result used | 799.952 mm |
| Applied thermal correction | −24 µm |
| Reported interval | 799.93549755 mm to 799.96850245 mm |
| Guarded acceptance zone | 799.96650245 mm to 800.03349755 mm |
| Simple acceptance | Accepted |
| Guarded result | Indeterminate |
| Closest decision margin | −14.50245 µm |
| Effective degrees of freedom | 88646.4 |
| Coverage basis | Fixed k = 2 |
Decision based on the measured interval, including expanded uncertainty. The illustrated three-zone guard rule accepts values whose full ±U interval lies inside spec, rejects those wholly outside, and flags overlap. A contract may specify another rule, correlations, temperature correction or uncertainty coverage.