Flange load & viewport stress / Worked example

Radial Seal Sapphire Feedthrough

A 34 mm sapphire window seats in a radial gland. Enter the assembled radial clearance for the squeeze calculation.

Readout ↓

Inputs

Plate and atmospheric load
Pa
Pa
mm
mm
mm
MPa
Enter 0 for a clamp or to omit equal load sharing.
Seal and gland
mm
mm
mm

Live readout

Viewport and seal screen pass
Net force215.2NBending stress3.249MPaDeflection2.453e-4mmSafety factor84.65Seal Ø 52 mmViewport safety factorSeal squeeze / gland fillActual SF84.6Minimum SF5Gland fill77.3%
Pressure differential
1.013e5 Pa
Atmospheric resultant
215.2 N
Resultant per fastener (equal share)
53.8 N
Peak bending stress
3.249 MPa
Screening allowable stress
55 MPa
Center deflection
2.453e-4 mm
Material safety factor
84.65
Required safety factor
5
O-ring squeeze
21.76%
O-ring gland fill
77.35%

    Reading this example

    Sapphire properties depend on orientation and finish. Replace the placeholder strength with a qualified viewport value.

    Model & assumptions

    Atmospheric resultant

    F = ΔP πDseal²/4

    The atmosphere usually seats an evacuated assembly. Equal force per fastener is a load share only. Determine bolt preload, clamp and flange ratings from the assembly design.

    Circular plate

    σsimple = 3(3+ν)ΔPr²/(8t²) · σclamped = 3ΔPr²/(4t²)

    The simple-support maximum is at the center. For an ideal clamp, maximum bending is at the edge. Deflection follows small-deflection thin-plate theory. The screen uses safety factor 4 for steel and 5 for brittle viewports.

    Elastomer gland

    Squeeze = 1 − h/d · Fill = (πd²/4)/(hw)

    Use assembled clearance h for axial or radial compression. The screen accepts 15% to 30% squeeze and fill below 85%. Fill at or above 100% exceeds the modeled gland capacity. CF copper gasket checks use assembly data.