Flange load & viewport stress / Worked example

Clamped 304 Steel Blank Cover

A 180 mm steel blank plate closes a high-vacuum vessel with a 220 mm seal diameter.

Readout ↓

Inputs

Plate and atmospheric load
Pa
Pa
mm
mm
mm
MPa
Enter 0 for a clamp or to omit equal load sharing.
Seal and gland

Live readout

Viewport and seal screen pass
Net force3852NBending stress7.599MPaDeflection8.114e-3mmSafety factor26.98Seal Ø 220 mmViewport safety factorCF metal gasketActual SF27Minimum SF4SealCopper
Pressure differential
1.013e5 Pa
Atmospheric resultant
3852 N
Resultant per fastener (equal share)
321 N
Peak bending stress
7.599 MPa
Screening allowable stress
51.25 MPa
Center deflection
8.114e-3 mm
Material safety factor
26.98
Required safety factor
4
O-ring squeeze
CF metal seal
O-ring gland fill
CF metal seal

    Reading this example

    Use the clamped edge result only if the joint provides the boundary condition. The per-fastener force is a share of the resultant.

    Model & assumptions

    Atmospheric resultant

    F = ΔP πDseal²/4

    The atmosphere usually seats an evacuated assembly. Equal force per fastener is a load share only. Determine bolt preload, clamp and flange ratings from the assembly design.

    Circular plate

    σsimple = 3(3+ν)ΔPr²/(8t²) · σclamped = 3ΔPr²/(4t²)

    The simple-support maximum is at the center. For an ideal clamp, maximum bending is at the edge. Deflection follows small-deflection thin-plate theory. The screen uses safety factor 4 for steel and 5 for brittle viewports.

    Elastomer gland

    Squeeze = 1 − h/d · Fill = (πd²/4)/(hw)

    Use assembled clearance h for axial or radial compression. The screen accepts 15% to 30% squeeze and fill below 85%. Fill at or above 100% exceeds the modeled gland capacity. CF copper gasket checks use assembly data.