Vacuum Flange Bolt Load, Viewport Stress & O-Ring Squeeze
Screen CF and ISO-KF vacuum loads, thin circular viewport bending, safety factor, O-ring squeeze and gland fill.
Inputs
Seal and gland
Live readout
Viewport and seal screen pass- Pressure differential
- 1.013e5 Pa
- Atmospheric resultant
- 1345 N
- Resultant per fastener (equal share)
- 224.2 N
- Peak bending stress
- 5.277 MPa
- Screening allowable stress
- 9.6 MPa
- Center deflection
- 7.414e-3 mm
- Material safety factor
- 9.095
- Required safety factor
- 5
- O-ring squeeze
- 20.68%
- O-ring gland fill
- 74.37%
Model & assumptions
Atmospheric resultant
F = ΔP πDseal²/4
The atmosphere usually seats an evacuated assembly. Equal force per fastener is a load share only. Determine bolt preload, clamp and flange ratings from the assembly design.
Circular plate
σsimple = 3(3+ν)ΔPr²/(8t²) · σclamped = 3ΔPr²/(4t²)
The simple-support maximum is at the center. For an ideal clamp, maximum bending is at the edge. Deflection follows small-deflection thin-plate theory. The screen uses safety factor 4 for steel and 5 for brittle viewports.
Elastomer gland
Squeeze = 1 − h/d · Fill = (πd²/4)/(hw)
Use assembled clearance h for axial or radial compression. The screen accepts 15% to 30% squeeze and fill below 85%. Fill at or above 100% exceeds the modeled gland capacity. CF copper gasket checks use assembly data.