Flange load & viewport stress / Worked example
Radial Seal Sapphire Feedthrough
A 34 mm sapphire window seats in a radial gland. Enter the assembled radial clearance for the squeeze calculation.
Inputs
Seal and gland
Live readout
Viewport and seal screen pass- Pressure differential
- 1.013e5 Pa
- Atmospheric resultant
- 215.2 N
- Resultant per fastener (equal share)
- 53.8 N
- Peak bending stress
- 3.249 MPa
- Screening allowable stress
- 55 MPa
- Center deflection
- 2.453e-4 mm
- Material safety factor
- 84.65
- Required safety factor
- 5
- O-ring squeeze
- 21.76%
- O-ring gland fill
- 77.35%
Reading this example
Sapphire properties depend on orientation and finish. Replace the placeholder strength with a qualified viewport value.
Model & assumptions
Atmospheric resultant
F = ΔP πDseal²/4
The atmosphere usually seats an evacuated assembly. Equal force per fastener is a load share only. Determine bolt preload, clamp and flange ratings from the assembly design.
Circular plate
σsimple = 3(3+ν)ΔPr²/(8t²) · σclamped = 3ΔPr²/(4t²)
The simple-support maximum is at the center. For an ideal clamp, maximum bending is at the edge. Deflection follows small-deflection thin-plate theory. The screen uses safety factor 4 for steel and 5 for brittle viewports.
Elastomer gland
Squeeze = 1 − h/d · Fill = (πd²/4)/(hw)
Use assembled clearance h for axial or radial compression. The screen accepts 15% to 30% squeeze and fill below 85%. Fill at or above 100% exceeds the modeled gland capacity. CF copper gasket checks use assembly data.