Semiconductor case

JEDEC-style IC early-life screening

An illustrative pre-screen life fit for a packaged IC has falling hazard and a 200,000-hour characteristic life. Evaluate failure probability during the first 168 hours.

Inputs

h
h
Blank uses a two-parameter model.
h
0–1
PassMission meets reliability target
Reliability
99.0032%
Unreliability
0.9968%
Hazard rate
3.876e-5h⁻¹
Mean life
273,255h

Life distribution

Weibull PDF, cumulative failures, hazard and probability plotProbability density06.3e-61.3e-502.1e54.2e56.3e5Age (h)Cumulative failures0%50%100%02.1e54.2e56.3e5Age (h)Hazard rate06.9e-61.4e-502.1e54.2e56.3e5Age (h)Weibull probability1%10%90%-8.23-4.91-1.591.72ln((t − γ)/η)ModelMission / goal

The markers follow mission age. The probability plot uses age since location γ and a transformed failure-probability scale.

Download

Detailed results

B1 life
168.8347 h
B10 life
6,272.743 h
B50 life
113,801 h
Age at target R*
168.8347 h
Model location γ
0 h
Failure regime
Infant mortality

Move mission age toward zero to see the early-life hazard rise. A population fit supports comparisons across lots under the same screening conditions.

Formula trace

  1. z = ((t − γ) / η)ᵝ for t ≥ γAt mission age 168 h, z = 0.01001801.
  2. R(t) = exp(−z) · F(t) = −expm1(−z)R(t) = 0.990032 and F(t) = 0.009968.
  3. h(t) = (β / η) ((t − γ) / η)ᵝ⁻¹h(t) = 3.876e-5 per hour. The hazard is zero before γ.
  4. MTTF = γ + η Γ(1 + 1/β)Mean life = 273,254.9 h.
  5. Bₚ = γ + η [−ln(1−p)]¹⁄ᵝB10 = 6,272.743 h. Use p = 1−R* for the target age.

Model assumptions

Use parameters fitted to one population and failure mechanism. The optional nonnegative location is a physical age before which the model permits no failures.

Method and sources

Related examples