Reference
Methodology
Equations, input conventions and assumptions for each model in the lab.
Weibull life
R(t) = exp(−[(t−γ)/η]ᵝ), for t ≥ γ
Shape β determines how hazard changes with age. At β = 1 the model reduces to the exponential. For ages below the nonnegative location γ, reliability is 1. The Weibull probability panel plots ln(−ln(1−F)) against ln((t−γ)/η).
The mean evaluates Γ(1+1/β) in log space using a Lanczos approximation. B-lives use the analytically inverted CDF. The model accepts a fitted parameter set and does not estimate it from failure data.
Arrhenius & Peck
AF = exp[(Eₐ/k)(1/Tuse−1/Tstress)] × (RHstress/RHuse)ⁿ
Absolute temperatures are in kelvin. Activation energy is in eV and k = 8.617333262145 × 10⁻⁵ eV/K. The optional Peck term is a relative-humidity ratio, so its percent units cancel.
Multiply exposure per device by the acceleration factor, then by the count for pooled hours. Zero-failure FIT uses the pooled, field-equivalent exposure. Higher stress must accelerate the same failure mechanism.
Thermal cycling
AF = (ΔTtest/ΔTuse)ᵐ (fuse/ftest)ᵠ exp[(Eₐ/k)(1/Tmax,use−1/Tmax,test)]
Use temperature differences for the swing ratio and absolute temperatures for the peak term. Convert cycles to years using the field cycles per day and 365 days per year.
The factor expresses field cycles per laboratory cycle. The frequency term follows the per-cycle Norris–Landzberg convention. Use swing as a strain proxy only for comparable assemblies and material geometry.
System RBD
Rsys = Pr(at least k blocks survive); MTTFsys = ∫₀∞ Rsys(t) dt
Series requires all blocks. Active parallel requires one. A k-out-of-n system uses an exact finite Bernoulli sum, with identical probabilities in the binomial case and a Poisson-binomial recurrence for unequal blocks.
Cold standby uses Pr(Poisson(t/MTBF) ≤ n−1). Equal exponential active blocks have MTTF/MTBF = Σ 1/j from j=k to n. Unequal active blocks use log-age quadrature, except series, which has a closed-form rate sum.
Reliability test sizing
MTBFₗ = 2 Ttotal / χ², with Pr(Chi²₂ᵣ₊₂ ≥ χ²) = 1−CL
The chi-square cutoff has left-tail probability CL. Use total observed time at risk and independent exponential or homogeneous Poisson-process assumptions. Zero failures reduce to Ttotal / [−ln(1−CL)].
A binomial success run needs ceil(ln(1−CL)/ln(R*)) all-pass devices. A Bayesian run uses a Beta(1,1) prior and one fewer device at the same numeric credibility target, with a minimum of one observed mission. The two claims use different interpretations of probability.
Repairable availability
Aᵢ = MTBF/(MTBF+MTTR); Aₒ = MTBF/(MTBF+MTTR+MDT)
MTBF is mean uptime per renewal cycle. Include corrective repair in MTTR and any extra downtime per cycle in MDT. The annual budget uses 8,760 hours.
For the two-state model starting up, A(t) approaches Aᵢ exponentially at rate 1/MTBF + 1/MTTR. Zero MTTR is the instantaneous repair limit. The operational nines tier counts factors of ten in the steady-state downtime fraction.
Poisson spare parts
λ = ML/MTBF; Pr(D ≤ S) = Q(S+1, λ)
The protection target is the chance demand fits on the shelf throughout a fixed lead time, also called cycle service level. Expected backorders give the expected number of units by which demand exceeds stock.
The Poisson tails are evaluated using the regularized incomplete gamma function. Binary search gives the smallest whole stock count that reaches the target. A stable upper-tail recurrence gives expected backorders when stock exceeds the mean.
Preventive replacement
C(T) = [CₚR(T) + C𝒻F(T)] / ∫₀ᵀ R(u) du
The policy replaces a failed component immediately or replaces a surviving component at age T. Each change restarts an independent Weibull life, with the same cost structure.
Adaptive composite 16-point Gauss–Legendre quadrature evaluates expected cycle time. Bisection of the renewal-cost slope in log cumulative hazard finds the finite optimum. Shape β ≤ 1 or C𝒻 ≤ Cₚ gives the run-to-failure limit.
Units and precision
Canonical input units are hours, Celsius and Celsius temperature intervals. A day is 24 hours and a modeled year is 365 days. Unit controls convert display strings from the stored canonical value on each change. FIT always means failures per billion hours.
Nonnegative domains reject negative zero, including negative numbers that underflow to zero during parsing. Probabilities exclude 0 and 1 unless a field defines a closed endpoint. An attained target includes equality. Decisions use unrounded calculation values. Inputs and results in JSON retain floating-point precision.
RBD supports up to 64 blocks and Poisson sizing supports mean demand up to 100,000. The test calculator supports up to 10,000 observed failures. Worked cases are illustrative settings for calculation practice and require independent inputs for an actual qualification decision.