WeldMetalLab

AWS D1.1 · AISC 360

E80 eligible transverse fillet under ASD

A straight E80 weld is loaded transverse to the seam and the engineer has confirmed direction-factor eligibility.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Weld and load
mm
mm
°
Use the increase only where the governing specification permits it.
kN
Leg limits
mm
mm

Live weld sheet

Updated from inputs
Fillet throat and forceEffective throat 4.949 mm. LRFD resistance 331.67 kN. ASD allowable load 221.11 kN. Applied direction factor 1.5 THROAT4.949mmLRFD331.67kNASD221.11kNLOAD FACTOR1.5 FILLET THROAT AND FORCE Leg 7 mmLoad angle 90 °E80xx LEG & WELD LOADPASS
Pass · within screen

Leg & weld load · 5 mm to 11 mm · 63.3 % load utilization.

Result details

Effective throat4.949 mm
LRFD resistance331.67 kN
ASD allowable load221.11 kN
Applied direction factor1.5
Nominal 0.707 × leg4.949 mm
Effective weld length180 mm
Effective throat area890.82 mm²
Electrode classification strength551.6 MPa
Angle-only factor1.5
Nominal weld-metal resistance442.22 kN
Governing plate thickness13 mm
Minimum nominal leg5 mm
Maximum edge leg11 mm
Demand / applicable resistance63.3 %
Weld-metal load margin81.11 kN

Worked example

Starting inputs

Equal leg size
7 mm
Weld length
180 mm
Electrode strength
E80xx
Angle to weld axis
90 °
Directional increase
Eligible load path
Demand basis
ASD service
Weld load demand
140 kN

Baseline results

Effective throat
4.949 mm
LRFD resistance
331.67 kN
ASD allowable load
221.11 kN
Applied direction factor
1.5

The 4.949 mm effective throat over 180 mm gives 890.82 mm² of weld area. With direction factor 1.5, compare the 81.11 kN signed resistance margin with zero.

Try it. At 90° the factor reaches 1.50. Use the ASD resistance with the entered service-level demand.

Calculation method

tₑ = 0.707w · LRFD = 0.75(0.60FEXX)tₑLₑk · ASD = 0.30FEXX·tₑLₑk

The angle θ is measured from the weld axis. The angle-only factor is 1 + 0.50·sin¹·⁵θ. Use 1.00 unless the selected weld condition permits the increase. Check strain compatibility for the actual weld group. AISC limits effective leg to L/4 for a short weld. For end loading, β reduces length above L/w = 100 and effective length is limited to 180w beyond L/w = 300.

The AWS screen uses the thinner piece for low-hydrogen welding and the thicker piece for the non-low-hydrogen case without qualified crack-prevention preheat. The latter case carries a single-pass condition. AISC uses the thinner piece. AWS cyclic service adds its separate minimum. The conservative edge maximum reserves 2 mm or 1/16 in at and above the corresponding quarter-inch class threshold.

The table basis fixes the inch or metric series even when you switch display units. The capacity is for one straight weld and weld metal only. Check base-metal limit states, eccentricity, fatigue and any qualified joint exceptions separately.

References

More worked examples