WeldMetalLab

AWS D1.1 · AISC 360

Fillet Weld Throat & Shear Strength

Calculate effective throat, LRFD and ASD weld-metal resistance, and nominal fillet leg limits.

Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.

Inputs

Weld and load
mm
mm
°
Use the increase only where the governing specification permits it.
kN
Leg limits
mm
mm

Live weld sheet

Updated from inputs
Fillet throat and forceEffective throat 4.242 mm. LRFD resistance 138.19 kN. ASD allowable load 92.13 kN. Applied direction factor 1 THROAT4.242mmLRFD138.19kNASD92.13kNLOAD FACTOR1 FILLET THROAT AND FORCE Leg 6 mmLoad angle 45 °E70xx LEG & WELD LOADPASS
Pass · within screen

Leg & weld load · 5 mm to 10 mm · 57.9 % load utilization.

Result details

Effective throat4.242 mm
LRFD resistance138.19 kN
ASD allowable load92.13 kN
Applied direction factor1
Nominal 0.707 × leg4.242 mm
Effective weld length150 mm
Effective throat area636.3 mm²
Electrode classification strength482.6 MPa
Angle-only factor1.297
Nominal weld-metal resistance184.26 kN
Governing plate thickness12 mm
Minimum nominal leg5 mm
Maximum edge leg10 mm
Demand / applicable resistance57.9 %
Weld-metal load margin58.19 kN

Calculation method

tₑ = 0.707w · LRFD = 0.75(0.60FEXX)tₑLₑk · ASD = 0.30FEXX·tₑLₑk

The angle θ is measured from the weld axis. The angle-only factor is 1 + 0.50·sin¹·⁵θ. Use 1.00 unless the selected weld condition permits the increase. Check strain compatibility for the actual weld group. AISC limits effective leg to L/4 for a short weld. For end loading, β reduces length above L/w = 100 and effective length is limited to 180w beyond L/w = 300.

The AWS screen uses the thinner piece for low-hydrogen welding and the thicker piece for the non-low-hydrogen case without qualified crack-prevention preheat. The latter case carries a single-pass condition. AISC uses the thinner piece. AWS cyclic service adds its separate minimum. The conservative edge maximum reserves 2 mm or 1/16 in at and above the corresponding quarter-inch class threshold.

The table basis fixes the inch or metric series even when you switch display units. The capacity is for one straight weld and weld metal only. Check base-metal limit states, eccentricity, fatigue and any qualified joint exceptions separately.

References

Worked examples