Fit-up · Restraint
Negative weld offset and reverse counter-set
A fixture coordinate system puts the weld below the section centroid.
Engineering screening only. Verify the applicable code, material and qualified WPS/PQR before production use.
Inputs
Live weld sheet
Updated from inputsBow tolerance · 17.639 mm magnitude vs 3 mm tolerance.
Result details
| Free transverse shrinkage | 0.72 mm |
|---|---|
| Free angular rotation | 1.13 ° |
| Bow under entered restraint | -17.639 mm |
| Opposite trial counter-camber | 17.639 mm |
| Longitudinal tendon force | 645.25 kN |
| Signed eccentric moment | -30.972 kN·m |
| Free signed bow | -19.599 mm |
| Held transverse shrinkage | 0.648 mm |
| Held angular rotation | 1.02 ° |
| Remaining bow tolerance | -14.639 mm |
Worked example
Starting inputs
- Joint family
- Fillet weld
- Plate or flange thickness
- 16 mm
- Deposited weld area
- 96 mm²
- Net heat per pass
- 1.05 kJ/mm
- Effective passes
- 3
- Angular balance
- 30 %
- Member span
- 4.5 m
Baseline results
- Free transverse shrinkage
- 0.72 mm
- Free angular rotation
- 1.13 °
- Bow under entered restraint
- -17.639 mm
- Opposite trial counter-camber
- 17.639 mm
A 645.25 kN tendon acting at -48 mm gives a signed moment of -30.972 kN·m. Free bow is -19.599 mm before applying the entered restraint reduction.
Try it. The bow changes sign with the offset. The suggested trial counter-set takes the opposite sign.
Calculation method
Δₜ ≈ k(C·A/t + Cg·g) · F ≈ 0.335EαQ/(ρc) · δ ≈ (F·e)L²/(8EI)
The free steel butt fit-up estimate uses C = 0.20 and Cg = 0.05. The fillet approximation uses C = 0.12 and no gap term. Apply a shop calibration multiplier to these estimates and to the angular scale αQ/(ρc·t²). Angular balance reduces rotation. The simple thermal estimate uses the entered effective pass count and typical steel heat capacity and expansion.
The tendon force acts at the signed weld offset to produce an approximately constant bending moment. Bow uses small-deflection constant curvature over the span. The restraint percentage is a sensitivity input applied to displacement only. Released parts may spring back, and strong restraint can raise residual stress and cracking risk.
The counter-camber is the signed opposite of the modeled held bow. Treat it as a trial adjustment. Confirm geometry and distortion on a representative weld, especially with thin plates or highly eccentric seams.