Tank engineering

Aquarium Volume, Glass Thickness & Floor Load Calculator

Calculate aquarium gallons, filled weight, glass thickness screening and floor load for rectangular, cube, bowfront and cylindrical tanks.

Inputs

View results
Inside the tank

Density estimates at about 25 °C.

in
in

For a bowfront, measure to the line connecting the two front corners.

in
in

Measure from the inside bottom to the water line.

US gal

Enter actual water displaced by rock, substrate and internal hardware.

Glass and support

Applies to flat walls. Curved wall strength needs a separate design.

in
×
lb

Enter 0 to estimate an all-glass shell.

Load on the stand
lb
lb
US gal
lb
lb
in
in
Filled system weight
848.7 lb
Average floor load
131.3 lb/ft²
Net display water
66.7 US gal
Glass cross-section and stand loadWater depth 19.5 in. Filled weight 848.69 lb. The arrows mark the floor loading zone. Tank elevationWater depth19.5 inGlass thickness0.375 in131.3 lb/ft²Stand footprint
Glass, water line & stand

Calculation details

Gross volume at brim
73.8 US gal
Water line before displacement
70.2 US gal
Net display and sump water
66.7 US gal
Display and sump water weight
555.3 lb
Estimated glass weight
118.4 lb
Installed safety factor
4.23 ×
Modeled thickness at target
0.355 in
Modeled wall deflection
0.012 in
  • Average loading uses the full stand footprint. Actual contact pressure and joist loads depend on your stand and floor.

Input measurements

Tank shape
Rectangular
Water type
Freshwater
Inside length or cube edge
47.5 in
Inside width
17.5 in
Inside height to brim
20.5 in
Filled water depth
19.5 in
Water displaced by contents
3.5 US gal
Flat panel support
Supported on all four edges
Installed glass thickness
0.375 in
Target safety factor
3.8 ×
Measured dry display tank
0 lb
Rock
35 lb
Substrate
50 lb
Sump water at operating level
0 US gal
Stand weight
75 lb
Dry sump and equipment
15 lb
Stand footprint length
49 in
Stand footprint width
19 in

Verify water volume with a measured fill before treating livestock. Have the tank, stand and floor checked for your installation before filling.

How the calculation works

The calculator multiplies inside plan area by water height. The bowfront adds a circular segment to the rectangle. The display volume subtracts measured displacement. Water mass includes the sump, then the scale adds the glass, rock, substrate, stand and equipment you enter.

For flat walls held on four edges, the thickness screen interpolates Warren Stilwell’s side-panel coefficients and uses 19.2 MPa reference strength for annealed float glass. The rimless option uses a fixed-base vertical strip with a free top and ignores the restraint from the side edges. The displayed safety factor compares that model with the installed thickness. Check the base and seams separately with the manufacturer or an aquarium engineer.

The flat-wall deflection estimate uses 69 GPa elastic modulus and the installed thickness. It assumes small elastic deflections under water pressure. Verify actual edge support and the bottom separately.

Average footprint loading spreads the total weight across the stand’s full rectangle. For a footed stand, check the actual contact points, joist span, support direction and subfloor with a qualified structural professional before filling.

References

Frequently asked questions

Which tank dimensions belong in the water volume formula?

Measure inside the glass and use the actual water line. The outside dimensions are useful for placement, but they include the glass and any empty gap above the water.

Can the footprint load clear my floor for an aquarium?

Treat the footprint average as an inventory estimate. A professional needs the stand contact points, joist directions and spans, supporting walls and other loads to assess the floor.