Worked example
120-Gallon Rimless Aquarium Glass Thickness & Safety Factor
A 48 × 24 × 24 in nominal rimless tank has a 22.5 in working water line in this example. The 19 mm pane is screened as a free-top, fixed-base strip.
See the worked calculationInputs
Results
Edit inputs120-Gallon Rimless Aquarium Glass Thickness & Safety Factor
AquariumReefLab spec sheet · https://calcsheetlab.com/aquariumreeflab/guides/120-gallon-rimless-glass-thickness-safety-factor/
- Modeled thickness at target
- 0.758 in
- Filled system weight
- 1,490.4 lb
- Average floor load
- 175.2 lb/ft²
Calculation details
- Net display water
- 98.4 US gal
- Gross volume at brim
- 105.3 US gal
- Water line before displacement
- 101.9 US gal
- Net display and sump water
- 120.4 US gal
- Display and sump water weight
- 1,028 lb
- Estimated glass weight
- 287.5 lb
- Installed safety factor
- 3.7 ×
- Modeled wall deflection
- 0.0204 in
- The installed flat-wall safety factor is below the 3.8 screening target. Have the pane checked before filling.
- Average loading uses the full stand footprint. Actual contact pressure and joist loads depend on your stand and floor.
Input measurements
- Tank shape
- Rectangular
- Water type
- Saltwater
- Inside length or cube edge
- 46.5 in
- Inside width
- 22.5 in
- Inside height to brim
- 23.25 in
- Filled water depth
- 22.5 in
- Water displaced by contents
- 3.5 US gal
- Flat panel support
- Top-free rimless screening
- Installed glass thickness
- 0.74803 in
- Target safety factor
- 3.8 ×
- Measured dry display tank
- 0 lb
- Rock
- 35 lb
- Substrate
- 50 lb
- Sump water at operating level
- 22 US gal
- Stand weight
- 75 lb
- Dry sump and equipment
- 15 lb
- Stand footprint length
- 49 in
- Stand footprint width
- 25 in
Verify water volume with a measured fill before treating livestock. Have the tank, stand and floor checked for your installation before filling.
Worked calculation
These numbers use the original example measurements. The calculator above updates as you edit.
Screen the flat glass
t = √[βρgH³ × SF ÷ (19.2 MPa)] → 19.25 mm at SF 3.8
Use H = 571.5 mm, β = 1 and water density 1,023 kg/m³ in consistent units. The selected 19 mm pane yields an estimated factor of 3.7.
Find the actual water volume
(46.5 in × 22.5 in) × 22.5 in → 101.91 US gal at the line; − 3.5 US gal → 98.41 US gal net
The running sump adds 22 US gal for 120.41 US gal of working water.
Add the masses on the stand
1,027.96 lb water + 287.45 lb tank + 175 lb other = 1,490.42 lb
Estimate the shell from the bottom and wall areas, the glass thickness and 2.5 g/cm³ glass density.
Divide by the footprint
1,490.42 lb ÷ 8.507 ft² = 175.2 lb/ft²
Equivalent averages are 855.4 kg/m² and 175.2 lb/ft² across the stand rectangle.
Frequently asked questions
Why does lowering the fill line matter for a 120-gallon rimless pane?
The thickness screen depends on water depth cubed before taking the square root. Lowering the line changes the load much more than the small change in gallons suggests.
Can I apply the 19 mm rimless result to low-iron glass?
Ask the manufacturer for strength, support and installation limits for the exact panel. The tool uses a generic annealed-glass reference and does not check seams or defects.