Worked example

120-Gallon Rimless Aquarium Glass Thickness & Safety Factor

A 48 × 24 × 24 in nominal rimless tank has a 22.5 in working water line in this example. The 19 mm pane is screened as a free-top, fixed-base strip.

See the worked calculation

Inputs

View results
Inside the tank

Density estimates at about 25 °C.

in
in

For a bowfront, measure to the line connecting the two front corners.

in
in

Measure from the inside bottom to the water line.

US gal

Enter actual water displaced by rock, substrate and internal hardware.

Glass and support

Applies to flat walls. Curved wall strength needs a separate design.

in
×
lb

Enter 0 to estimate an all-glass shell.

Load on the stand
lb
lb
US gal
lb
lb
in
in
Modeled thickness at target
0.758 in
Filled system weight
1,490.4 lb
Average floor load
175.2 lb/ft²
Glass cross-section and stand loadWater depth 22.5 in. Filled weight 1,490.42 lb. The arrows mark the floor loading zone. Tank elevationWater depth22.5 inGlass thickness0.748 in175.2 lb/ft²Stand footprint
Glass, water line & stand

Calculation details

Net display water
98.4 US gal
Gross volume at brim
105.3 US gal
Water line before displacement
101.9 US gal
Net display and sump water
120.4 US gal
Display and sump water weight
1,028 lb
Estimated glass weight
287.5 lb
Installed safety factor
3.7 ×
Modeled wall deflection
0.0204 in
  • The installed flat-wall safety factor is below the 3.8 screening target. Have the pane checked before filling.
  • Average loading uses the full stand footprint. Actual contact pressure and joist loads depend on your stand and floor.

Input measurements

Tank shape
Rectangular
Water type
Saltwater
Inside length or cube edge
46.5 in
Inside width
22.5 in
Inside height to brim
23.25 in
Filled water depth
22.5 in
Water displaced by contents
3.5 US gal
Flat panel support
Top-free rimless screening
Installed glass thickness
0.74803 in
Target safety factor
3.8 ×
Measured dry display tank
0 lb
Rock
35 lb
Substrate
50 lb
Sump water at operating level
22 US gal
Stand weight
75 lb
Dry sump and equipment
15 lb
Stand footprint length
49 in
Stand footprint width
25 in

Verify water volume with a measured fill before treating livestock. Have the tank, stand and floor checked for your installation before filling.

Worked calculation

These numbers use the original example measurements. The calculator above updates as you edit.

  1. Screen the flat glass

    t = √[βρgH³ × SF ÷ (19.2 MPa)] → 19.25 mm at SF 3.8

    Use H = 571.5 mm, β = 1 and water density 1,023 kg/m³ in consistent units. The selected 19 mm pane yields an estimated factor of 3.7.

  2. Find the actual water volume

    (46.5 in × 22.5 in) × 22.5 in → 101.91 US gal at the line; − 3.5 US gal → 98.41 US gal net

    The running sump adds 22 US gal for 120.41 US gal of working water.

  3. Add the masses on the stand

    1,027.96 lb water + 287.45 lb tank + 175 lb other = 1,490.42 lb

    Estimate the shell from the bottom and wall areas, the glass thickness and 2.5 g/cm³ glass density.

  4. Divide by the footprint

    1,490.42 lb ÷ 8.507 ft² = 175.2 lb/ft²

    Equivalent averages are 855.4 kg/m² and 175.2 lb/ft² across the stand rectangle.

Frequently asked questions

Why does lowering the fill line matter for a 120-gallon rimless pane?

The thickness screen depends on water depth cubed before taking the square root. Lowering the line changes the load much more than the small change in gallons suggests.

Can I apply the 19 mm rimless result to low-iron glass?

Ask the manufacturer for strength, support and installation limits for the exact panel. The tool uses a generic annealed-glass reference and does not check seams or defects.