Bare roadbed reaction

Set granular subbase thickness to zero to show k without a structural subbase adjustment.

Design readout

Powell Mᵣ
7,157
psi
Support k
368.9
pci
Frost depth
21.36
in
Depth margin
-5.36
in

Frost penetration profile

Frost penetration profileTHERMAL PROFILEDEPTH BELOW SURFACERESISTANT DEPTH16 inFROST FRONT21.36 inSURFACE INDEX350 °F·daysBARE K368.9 pciCOMPOSITE K368.9 pci
Both depths are measured from the surface. The frost model uses one equivalent thermal material.

Frost reaches below section

Marker shows resistant depth relative to modeled frost depth.

Calculation ledger
Linear CBR modulus E
7,500 psi
Bare subgrade k from Powell modulus
368.92 pci
Uncorrected Stefan depth
27.39 in
Surface freezing index
350 °F·days

Inputs

Changes update results

Subgrade and pavement
%
%
lb/ft³
in
in
ksi
Thermal assumptions
°F·days
Btu/(h·ft·°F)

Set λ to 1 for the Stefan result. Calibrate the thermal inputs using local data.

Work through this example

  1. Compare two CBR-to-modulus correlations for the soaked soil.
  2. Use Powell Mᵣ with granular subbase thickness and stiffness to estimate composite k.
  3. Compute frost depth from the surface freezing index, conductivity and soil water, then compare with the resistant section.

Estimated composite k equals bare k here. Add a realistic granular subbase to compare.

The linear CBR correlation is a low-CBR fine-soil screen. Composite k uses the FHWA chart range for thickness and roadbed stiffness and omits seasonal, erosion and bedrock corrections. Use measured support and a layered thermal analysis where warranted.

Read the equations and sources