Both depths are measured from the surface. The frost model uses one equivalent thermal material.
High CBR correlation caution
CBR exceeds 10%. Verify the support correlations with measured modulus. Marker shows resistant depth relative to modeled frost depth.
Calculation ledger
Linear CBR modulus E
27,000 psi
Bare subgrade k from Powell modulus
837.46 pci
Uncorrected Stefan depth
33.61 in
Surface freezing index
280 °F·days
Inputs
Changes update results
Work through this example
Compare two CBR-to-modulus correlations for the soaked soil.
Use Powell Mᵣ with granular subbase thickness and stiffness to estimate composite k.
Compute frost depth from the surface freezing index, conductivity and soil water, then compare with the resistant section.
Compare the spread of Powell and linear estimates. Verify the measured modulus before using either in design.
The linear CBR correlation is a low-CBR fine-soil screen. Composite k uses the FHWA chart range for thickness and roadbed stiffness and omits seasonal, erosion and bedrock corrections. Use measured support and a layered thermal analysis where warranted.
Subgrade CBR & Frost Penetration · US customary units
High CBR correlation caution. CBR exceeds 10%. Verify the support correlations with measured modulus. Marker shows resistant depth relative to modeled frost depth.
Inputs
Soaked CBR
18%
Gravimetric moisture w
8%
Dry density γᵈ
119 lb/ft³
Frost-resistant section Hₚₐᵥ
42 in
Rigid granular subbase depth
8 in
Granular subbase modulus
40 ksi
Air freezing index
400 °F·days
Mean thermal conductivity
0.8 Btu/(h·ft·°F)
Air-to-surface factor n
0.7
Berggren correction λ
0.78
Results
Powell resilient modulus
16,246.7 psi
Estimated composite reaction
837.2 pci
Modified Berggren depth
26.21 in
Frost-resistant depth margin
15.79 in
Linear CBR modulus E
27,000 psi
Bare subgrade k from Powell modulus
837.46 pci
Uncorrected Stefan depth
33.61 in
Surface freezing index
280 °F·days
The linear CBR correlation is a low-CBR fine-soil screen. Composite k uses the FHWA chart range for thickness and roadbed stiffness and omits seasonal, erosion and bedrock corrections. Use measured support and a layered thermal analysis where warranted.