Uncorrected Stefan depth

Set the Berggren correction to 1.0 to recover the Stefan depth.

Design readout

Powell Mᵣ
8,042.8
psi
Support k
481
pci
Frost depth
41.68
in
Depth margin
-6.68
in

Frost penetration profile

Frost penetration profileTHERMAL PROFILEDEPTH BELOW SURFACERESISTANT DEPTH35 inFROST FRONT41.68 inSURFACE INDEX608 °F·daysBARE K414.6 pciCOMPOSITE K481 pci
Both depths are measured from the surface. The frost model uses one equivalent thermal material.

Frost reaches below section

Subbase modulus is outside the FHWA guidance of 15–50 ksi and less than 4 × roadbed modulus. Marker shows resistant depth relative to modeled frost depth.

Calculation ledger
Linear CBR modulus E
9,000 psi
Bare subgrade k from Powell modulus
414.58 pci
Uncorrected Stefan depth
41.68 in
Surface freezing index
608 °F·days

Inputs

Changes update results

Subgrade and pavement
%
%
lb/ft³
in
in
ksi
Thermal assumptions
°F·days
Btu/(h·ft·°F)

Set λ to 1 for the Stefan result. Calibrate the thermal inputs using local data.

Work through this example

  1. Compare two CBR-to-modulus correlations for the soaked soil.
  2. Use Powell Mᵣ with granular subbase thickness and stiffness to estimate composite k.
  3. Compute frost depth from the surface freezing index, conductivity and soil water, then compare with the resistant section.

The corrected and uncorrected depths coincide. Change λ to 0.8 and check the proportional reduction.

The linear CBR correlation is a low-CBR fine-soil screen. Composite k uses the FHWA chart range for thickness and roadbed stiffness and omits seasonal, erosion and bedrock corrections. Use measured support and a layered thermal analysis where warranted.

Read the equations and sources