12-Inch Subwoofer in a 2.0 ft³ Box Tuned to 32 Hz

Use a 2.0 ft³ net box with a 10 in × 2 in opening and a 32 Hz tuning target. The entered box volume is the air behind the 12-inch driver after accounting for the port.

Inputs

Driver and sealed alignment
Hz
ft³
Vented box and port
ft³
Hz
in
in
Air-speed check
ft³/s
°F

Results

Physical port length per duct
22.48in
Net modeled enclosure volume
2ft³
Peak port Mach number
0.0384
Sealed system Qtc
0.651
Sealed −3 dB frequency
47.46Hz
Sealed box for target Qtc
1.53ft³
Total open port area
20in²
Estimated peak port air speed
43.23ft/s
Area needed at entered Mach limit
15.35in²
Mach screen
Within limit
Port duct displacement
0.26ft³
Enclosure and duct section
Enclosure and duct sectionNet air volume2 ft³1 × slot · 32 Hz22.48 in per ductMach 0.0384Limit 0.05

The cross-section is schematic. The duct span responds to the computed length, and the Mach reading uses the entered airflow.

Sealed and vented response
Sealed and vented responseRelative level (dB)9193979160-48-36-24-1201224Frequency (Hz)VentedSealed

Small-signal curves normalized to the upper passband. The dashed line marks the target port tuning.

Small-signal response

Frequency (Hz)Sealed (dB)Vented (dB)
9.33-26.77-40.53
28-8.82-3.96
32-7.03-0.6
47.46-3.012.19
80-0.770.92
120-0.270.41

Worked calculation

  1. Calculate the total open area

    S = 1 × 25.4 × 5.08 = 129.032 cm²

  2. Subtract the end correction from effective duct length

    L = S(c ÷ 2πFb)² ÷ Vb − ΔL = 66.468 − 9.357 = 57.111 cm

  3. Check peak air velocity

    u = 0.17 m³/s ÷ 0.0129032 m² = 13.175 m/s. Mach = u ÷ 343.42 = 0.03836

What the example shows

The 20 in² opening needs a duct about 22.5 in long with the selected end correction. A folded layout needs room for the turn and clearance at the inner mouth.

Model assumptions

  • Use net internal air volume after removing the displacement of the driver, braces and port. The listed vent displacement covers the air duct, with wall material handled separately.
  • The sealed and vented curves assume small signals. The vented curve includes driver Qts and ideal Helmholtz behavior. Confirm real tuning and excursion with a measurement or a driver model that includes losses.
  • Air speed uses peak volume flow at the port, supplied from a measurement or a simulation at your target level. The Mach limit is an editable design screen. Slot end correction uses an equivalent round radius.