12-Inch Subwoofer in a 2.0 ft³ Box Tuned to 32 Hz
Use a 2.0 ft³ net box with a 10 in × 2 in opening and a 32 Hz tuning target. The entered box volume is the air behind the 12-inch driver after accounting for the port.
- Driver resonance (Fs)
- 28 Hz
- Driver total Q (Qts)
- 0.42
- Driver equivalent volume (Vas)
- 2.8 ft³
- Target sealed Qtc
- 0.707
- Solve for
- Port length from net volume
- Net internal volume
- 2 ft³
- Port tuning (Fb)
- 32 Hz
- Port shape
- Rectangular slot
- Inside slot width
- 10 in
- Inside slot height
- 2 in
- Identical ports
- 1
- Port end correction
- One flanged, one free
- Peak volume flow through all ports
- 6.003493 ft³/s
- Peak Mach limit
- 0.05
- Air temperature
- 68 °F
Results
- Physical port length per duct
- 22.48in
- Net modeled enclosure volume
- 2ft³
- Peak port Mach number
- 0.0384
- Sealed system Qtc
- 0.651
- Sealed −3 dB frequency
- 47.46Hz
- Sealed box for target Qtc
- 1.53ft³
- Total open port area
- 20in²
- Estimated peak port air speed
- 43.23ft/s
- Area needed at entered Mach limit
- 15.35in²
- Mach screen
- Within limit
- Port duct displacement
- 0.26ft³
The cross-section is schematic. The duct span responds to the computed length, and the Mach reading uses the entered airflow.
Small-signal curves normalized to the upper passband. The dashed line marks the target port tuning.
Small-signal response
| Frequency (Hz) | Sealed (dB) | Vented (dB) |
|---|---|---|
| 9.33 | -26.77 | -40.53 |
| 28 | -8.82 | -3.96 |
| 32 | -7.03 | -0.6 |
| 47.46 | -3.01 | 2.19 |
| 80 | -0.77 | 0.92 |
| 120 | -0.27 | 0.41 |
Worked calculation
Calculate the total open area
S = 1 × 25.4 × 5.08 = 129.032 cm²
Subtract the end correction from effective duct length
L = S(c ÷ 2πFb)² ÷ Vb − ΔL = 66.468 − 9.357 = 57.111 cm
Check peak air velocity
u = 0.17 m³/s ÷ 0.0129032 m² = 13.175 m/s. Mach = u ÷ 343.42 = 0.03836
What the example shows
The 20 in² opening needs a duct about 22.5 in long with the selected end correction. A folded layout needs room for the turn and clearance at the inner mouth.
Model assumptions
- Use net internal air volume after removing the displacement of the driver, braces and port. The listed vent displacement covers the air duct, with wall material handled separately.
- The sealed and vented curves assume small signals. The vented curve includes driver Qts and ideal Helmholtz behavior. Confirm real tuning and excursion with a measurement or a driver model that includes losses.
- Air speed uses peak volume flow at the port, supplied from a measurement or a simulation at your target level. The Mach limit is an editable design screen. Slot end correction uses an equivalent round radius.
Common questions
How much area does a 10 × 2 in slot give this 32 Hz box?
It gives 20 in² of open area. Use the clear inside dimensions after subtracting material thicknesses.
Does a 22.5 in duct have to be straight inside the 2 ft³ enclosure?
It can be folded with enough cross section through the bends. Measure along its centerline, preserve clearance at the mouth, and verify the tuning on the built cabinet.