Box Volume for a 4 × 12 in Round Port at 35 Hz
You have a round tube with 4 in inside diameter and 12 in usable straight length. Choose Net volume from fixed port to find the net enclosure size that tunes to 35 Hz.
- Driver resonance (Fs)
- 28 Hz
- Driver total Q (Qts)
- 0.42
- Driver equivalent volume (Vas)
- 2.8 ft³
- Target sealed Qtc
- 0.707
- Solve for
- Net volume from fixed port
- Fixed physical port length
- 12 in
- Port tuning (Fb)
- 35 Hz
- Port shape
- Round tube
- Inside tube diameter
- 4 in
- Identical ports
- 1
- Port end correction
- One flanged, one free
- Peak volume flow through all ports
- 6.003493 ft³/s
- Peak Mach limit
- 0.05
- Air temperature
- 68 °F
Results
- Net modeled enclosure volume
- 1.84ft³
- Physical port length per duct
- 12in
- Total open port area
- 12.57in²
- Peak port Mach number
- 0.0611
- Sealed system Qtc
- 0.667
- Sealed −3 dB frequency
- 47.3Hz
- Sealed box for target Qtc
- 1.53ft³
- Estimated peak port air speed
- 68.79ft/s
- Area needed at entered Mach limit
- 15.35in²
- Mach screen
- Above limit
- Port duct displacement
- 0.09ft³
The cross-section is schematic. The duct span responds to the computed length, and the Mach reading uses the entered airflow.
Small-signal curves normalized to the upper passband. The dashed line marks the target port tuning.
Small-signal response
| Frequency (Hz) | Sealed (dB) | Vented (dB) |
|---|---|---|
| 9.33 | -27.17 | -42.29 |
| 28 | -9.02 | -6.13 |
| 35 | -6.02 | 0.24 |
| 47.3 | -3.01 | 3.34 |
| 80 | -0.69 | 1.38 |
| 120 | -0.22 | 0.6 |
Worked calculation
Calculate the total open area
S = 1 × π × (10.16 ÷ 2)² = 81.073 cm²
Solve for net ported volume from a fixed duct
Vb = S(c ÷ 2πFb)² ÷ (L + ΔL) = 52.171 L with L = 30.48 cm and ΔL = 7.417 cm
What the example shows
The solve uses physical length plus the end correction in the denominator. Add the listed duct displacement and the actual solid parts when working out gross dimensions.
Model assumptions
- Use net internal air volume after removing the displacement of the driver, braces and port. The listed vent displacement covers the air duct, with wall material handled separately.
- The sealed and vented curves assume small signals. The vented curve includes driver Qts and ideal Helmholtz behavior. Confirm real tuning and excursion with a measurement or a driver model that includes losses.
- Air speed uses peak volume flow at the port, supplied from a measurement or a simulation at your target level. The Mach limit is an editable design screen. Slot end correction uses an equivalent round radius.
Common questions
How do flared ends change the fixed 4 × 12 in port estimate?
End shape changes the added acoustic length. Select the closest end condition and verify with impedance after assembly, especially for large flares.
Can I use outside diameter for the fixed round duct?
Use the clear internal diameter. The calculated air mass and area follow the unobstructed bore rather than the tube’s wall thickness.