Sealed 10-Inch Subwoofer Box for Qtc 0.707
A 10-inch driver has a 32 Hz free-air resonance, Qts 0.45 and Vas 45 L. Compare a convenient 30 L build with the calculated Qtc 0.707 target volume.
- Driver resonance (Fs)
- 32 Hz
- Driver total Q (Qts)
- 0.45
- Driver equivalent volume (Vas)
- 45 L
- Target sealed Qtc
- 0.707
- Solve for
- Port length from net volume
- Net internal volume
- 30 L
- Port tuning (Fb)
- 32 Hz
- Port shape
- Rectangular slot
- Inside slot width
- 25.4 cm
- Inside slot height
- 5.08 cm
- Identical ports
- 1
- Port end correction
- One flanged, one free
- Peak volume flow through all ports
- 170 L/s
- Peak Mach limit
- 0.05
- Air temperature
- 20 °C
Results
- Sealed box for target Qtc
- 30.65L
- Sealed system Qtc
- 0.712
- Sealed −3 dB frequency
- 50.29Hz
- Physical port length per duct
- 116.12cm
- Net modeled enclosure volume
- 30L
- Peak port Mach number
- 0.0384
- Total open port area
- 129.03cm²
- Estimated peak port air speed
- 13.18m/s
- Area needed at entered Mach limit
- 99cm²
- Mach screen
- Within limit
- Port duct displacement
- 14.98L
The cross-section is schematic. The duct span responds to the computed length, and the Mach reading uses the entered airflow.
Small-signal curves normalized to the upper passband. The dashed line marks the target port tuning.
Small-signal response
| Frequency (Hz) | Sealed (dB) | Vented (dB) |
|---|---|---|
| 10.67 | -27.05 | -37.32 |
| 32 | -8.57 | -3.52 |
| 50.29 | -3.01 | 1.12 |
| 80 | -0.61 | 1.11 |
| 120 | -0.12 | 0.58 |
Worked calculation
Find net volume for the sealed target
Vb = Vas ÷ [(Qtc ÷ Qts)² − 1] = 45 ÷ [(0.707 ÷ 0.45)² − 1] = 30.646 L
Find sealed resonance and damping
Qtc = 0.45 × √(1 + 45 ÷ 30) = 0.7115. Fc = 50.596 Hz. Solving |H| = 1/√2 gives F₃ = 50.285 Hz
What the example shows
A net 30 L volume yields Qtc around 0.712. The 0.707 target calculation is close enough to compare against bracing and driver displacement before choosing dimensions.
Model assumptions
- Use net internal air volume after removing the displacement of the driver, braces and port. The listed vent displacement covers the air duct, with wall material handled separately.
- The sealed and vented curves assume small signals. The vented curve includes driver Qts and ideal Helmholtz behavior. Confirm real tuning and excursion with a measurement or a driver model that includes losses.
- Air speed uses peak volume flow at the port, supplied from a measurement or a simulation at your target level. The Mach limit is an editable design screen. Slot end correction uses an equivalent round radius.
Common questions
Does Qtc 0.707 mean the sealed box is critically damped?
Qtc near 0.707 gives a maximally flat second-order magnitude response. Critical damping corresponds to Q = 0.5.
Can I put 30 L of gross volume on the sealed cut sheet?
The worksheet uses 30 L net. Add the volume displaced by the driver, braces and any other structures inside the enclosure.