Two 3-Inch Round Ports in a 1.75 ft³ Box at 34 Hz
A 1.75 ft³ box uses two 3 in internal-diameter round tubes to reach 34 Hz. Enter two ports and read the length for each tube.
- Driver resonance (Fs)
- 28 Hz
- Driver total Q (Qts)
- 0.42
- Driver equivalent volume (Vas)
- 2.8 ft³
- Target sealed Qtc
- 0.707
- Solve for
- Port length from net volume
- Net internal volume
- 1.75 ft³
- Port tuning (Fb)
- 34 Hz
- Port shape
- Round tube
- Inside tube diameter
- 3 in
- Identical ports
- 2
- Port end correction
- One flanged, one free
- Peak volume flow through all ports
- 4.590907 ft³/s
- Peak Mach limit
- 0.05
- Air temperature
- 68 °F
Results
- Physical port length per duct
- 16.54in
- Total open port area
- 14.14in²
- Peak port Mach number
- 0.0415
- Net modeled enclosure volume
- 1.75ft³
- Sealed system Qtc
- 0.677
- Sealed −3 dB frequency
- 47.23Hz
- Sealed box for target Qtc
- 1.53ft³
- Estimated peak port air speed
- 46.76ft/s
- Area needed at entered Mach limit
- 11.73in²
- Mach screen
- Within limit
- Port duct displacement
- 0.14ft³
The cross-section is schematic. The duct span responds to the computed length, and the Mach reading uses the entered airflow.
Small-signal curves normalized to the upper passband. The dashed line marks the target port tuning.
Small-signal response
| Frequency (Hz) | Sealed (dB) | Vented (dB) |
|---|---|---|
| 9.33 | -27.43 | -41.67 |
| 28 | -9.15 | -5.84 |
| 34 | -6.46 | -0.71 |
| 47.23 | -3.01 | 2.8 |
| 80 | -0.64 | 1.31 |
| 120 | -0.19 | 0.59 |
Worked calculation
Calculate the total open area
S = 2 × π × (7.62 ÷ 2)² = 91.207 cm²
Subtract the end correction from effective duct length
L = S(c ÷ 2πFb)² ÷ Vb − ΔL = 47.564 − 5.563 = 42.002 cm
Check peak air velocity
u = 0.13 m³/s ÷ 0.0091207 m² = 14.253 m/s. Mach = u ÷ 343.42 = 0.0415
What the example shows
The tubes contribute about 14.14 in² in total. Both openings share the air flow, and the end correction applies to each individual radius.
Model assumptions
- Use net internal air volume after removing the displacement of the driver, braces and port. The listed vent displacement covers the air duct, with wall material handled separately.
- The sealed and vented curves assume small signals. The vented curve includes driver Qts and ideal Helmholtz behavior. Confirm real tuning and excursion with a measurement or a driver model that includes losses.
- Air speed uses peak volume flow at the port, supplied from a measurement or a simulation at your target level. The Mach limit is an editable design screen. Slot end correction uses an equivalent round radius.
Common questions
Do I divide the physical length by two for a dual 3 in port box?
Use the listed length for each tube. A second duct adds open area, which increases the required effective length at the same tuning and net volume.
Does the calculation still apply if one round port is blocked?
Set the port count to one to see the geometry needed for the original target. Blocking one of two fixed ducts shifts the tuning.