Two 3-Inch Round Ports in a 1.75 ft³ Box at 34 Hz

A 1.75 ft³ box uses two 3 in internal-diameter round tubes to reach 34 Hz. Enter two ports and read the length for each tube.

Inputs

Driver and sealed alignment
Hz
ft³
Vented box and port
ft³
Hz
in
Air-speed check
ft³/s
°F

Results

Physical port length per duct
16.54in
Total open port area
14.14in²
Peak port Mach number
0.0415
Net modeled enclosure volume
1.75ft³
Sealed system Qtc
0.677
Sealed −3 dB frequency
47.23Hz
Sealed box for target Qtc
1.53ft³
Estimated peak port air speed
46.76ft/s
Area needed at entered Mach limit
11.73in²
Mach screen
Within limit
Port duct displacement
0.14ft³
Enclosure and duct section
Enclosure and duct sectionNet air volume1.75 ft³2 × round · 34 Hz16.54 in per ductMach 0.0415Limit 0.05

The cross-section is schematic. The duct span responds to the computed length, and the Mach reading uses the entered airflow.

Sealed and vented response
Sealed and vented responseRelative level (dB)9194082170-48-36-24-1201224Frequency (Hz)VentedSealed

Small-signal curves normalized to the upper passband. The dashed line marks the target port tuning.

Small-signal response

Frequency (Hz)Sealed (dB)Vented (dB)
9.33-27.43-41.67
28-9.15-5.84
34-6.46-0.71
47.23-3.012.8
80-0.641.31
120-0.190.59

Worked calculation

  1. Calculate the total open area

    S = 2 × π × (7.62 ÷ 2)² = 91.207 cm²

  2. Subtract the end correction from effective duct length

    L = S(c ÷ 2πFb)² ÷ Vb − ΔL = 47.564 − 5.563 = 42.002 cm

  3. Check peak air velocity

    u = 0.13 m³/s ÷ 0.0091207 m² = 14.253 m/s. Mach = u ÷ 343.42 = 0.0415

What the example shows

The tubes contribute about 14.14 in² in total. Both openings share the air flow, and the end correction applies to each individual radius.

Model assumptions

  • Use net internal air volume after removing the displacement of the driver, braces and port. The listed vent displacement covers the air duct, with wall material handled separately.
  • The sealed and vented curves assume small signals. The vented curve includes driver Qts and ideal Helmholtz behavior. Confirm real tuning and excursion with a measurement or a driver model that includes losses.
  • Air speed uses peak volume flow at the port, supplied from a measurement or a simulation at your target level. The Mach limit is an editable design screen. Slot end correction uses an equivalent round radius.