2 Vrms DAC Output to dBu, dBV and Vpp

A DAC specification lists a 2 Vrms sine at its analog output. Start with the measured voltage and calculate how that amplitude looks in line-level units.

Inputs

Signal input
Vrms
Converter calibration

Results

Level referenced to 0.775 Vrms
8.23dBu
Level referenced to 1 Vrms
6.02dBV
Sine peak-to-peak voltage
5.65685Vpp
RMS voltage
2Vrms
Mapped digital level
-13.77dBFS
Remaining digital headroom
13.77dB
Analog voltage for 0 dBFS
9.7567Vrms
Analog reference voltage
1.2283Vrms
Calibration limit
Within full scale
Digital alignment meter
Digital alignment meterDigital amplitude (dBFS)Within full scale-60-48-36-24-1204 dBu at -18 dBFS9.757 Vrms at full scale

The dashed marker indicates calibration. Illuminated segments track the amplitude on a −60 to 0 dBFS display.

Calibration landmarks

Digital level (dBFS)Voltage (Vrms)Analog level (dBu)
09.7566722
-64.8899216
-122.4507710
-181.228294
-240.6156-2
-480.03884-26

Worked calculation

  1. Convert the input signal through RMS voltage

    2 Vrms → 2 Vrms. Vpp = 2√2 × 2 = 5.656854 Vpp

  2. Compare the two analog decibel references

    dBu = 20 log₁₀(Vrms ÷ 0.775) = 8.235. dBV = 20 log₁₀(Vrms ÷ 1) = 6.021

  3. Map the voltage to the selected digital reference

    Digital level = 20 log₁₀(2 ÷ 9.756672) = -13.765 dBFS

What the example shows

A 2 Vrms sine is about +6.02 dBV and 5.657 Vpp. Its mapped dBFS is meaningful only for the calibration you select.

Model assumptions

  • Peak-to-peak conversion assumes a clean sine wave. Program material has a changing crest factor and dBFS calibration here does not measure LUFS or true peak.
  • The EBU and SMPTE presets pair their digital reference levels with common analog alignment voltages. Use Custom to enter the reference measured on your converter.
  • An analog signal can map above 0 dBFS. This flags the amount above the chosen converter calibration limit.