+4 dBu to RMS Volts and −18 dBFS
A console outputs a +4 dBu alignment sine. Patch it to a converter set to read −18 dBFS for that input and work out what a meter should show.
- Signal level
- 4 dBu
- Input scale
- dBu
- Alignment
- +4 dBu = −18 dBFS
Results
- RMS voltage
- 1.22829Vrms
- Mapped digital level
- -18dBFS
- Remaining digital headroom
- 18dB
- Level referenced to 0.775 Vrms
- 4dBu
- Level referenced to 1 Vrms
- 1.79dBV
- Sine peak-to-peak voltage
- 3.47414Vpp
- Analog voltage for 0 dBFS
- 9.7567Vrms
- Analog reference voltage
- 1.2283Vrms
- Calibration limit
- Within full scale
The dashed marker indicates calibration. Illuminated segments track the amplitude on a −60 to 0 dBFS display.
Calibration landmarks
| Digital level (dBFS) | Voltage (Vrms) | Analog level (dBu) |
|---|---|---|
| 0 | 9.75667 | 22 |
| -6 | 4.88992 | 16 |
| -12 | 2.45077 | 10 |
| -18 | 1.22829 | 4 |
| -24 | 0.6156 | -2 |
| -48 | 0.03884 | -26 |
Worked calculation
Convert the input signal through RMS voltage
4 dBu → 1.228292 Vrms. Vpp = 2√2 × 1.228292 = 3.474135 Vpp
Find the analog voltage at digital full scale
V0dBFS = 1.228292 ÷ 10^(-18 ÷ 20) = 9.75667 Vrms
Map the voltage to the selected digital reference
Digital level = 20 log₁₀(1.228292 ÷ 9.756672) = -18 dBFS
What the example shows
The console tone is about 1.228 Vrms and 3.474 Vpp. With this calibration, 18 more dB of sine amplitude reaches digital full scale.
Model assumptions
- Peak-to-peak conversion assumes a clean sine wave. Program material has a changing crest factor and dBFS calibration here does not measure LUFS or true peak.
- The EBU and SMPTE presets pair their digital reference levels with common analog alignment voltages. Use Custom to enter the reference measured on your converter.
- An analog signal can map above 0 dBFS. This flags the amount above the chosen converter calibration limit.
Common questions
Is +4 dBu always equal to −18 dBFS?
That equality follows from the chosen alignment. A different converter gain setting can make the same +4 dBu produce another digital reading.
What Vrms reading should I expect from the +4 dBu sine?
About 1.228 Vrms across the measurement terminals specified by the device. Use a meter that measures the tone frequency accurately.