+4 dBu to RMS Volts and −18 dBFS

A console outputs a +4 dBu alignment sine. Patch it to a converter set to read −18 dBFS for that input and work out what a meter should show.

Inputs

Signal input
dBu
Converter calibration

Results

RMS voltage
1.22829Vrms
Mapped digital level
-18dBFS
Remaining digital headroom
18dB
Level referenced to 0.775 Vrms
4dBu
Level referenced to 1 Vrms
1.79dBV
Sine peak-to-peak voltage
3.47414Vpp
Analog voltage for 0 dBFS
9.7567Vrms
Analog reference voltage
1.2283Vrms
Calibration limit
Within full scale
Digital alignment meter
Digital alignment meterDigital amplitude (dBFS)Within full scale-60-48-36-24-1204 dBu at -18 dBFS9.757 Vrms at full scale

The dashed marker indicates calibration. Illuminated segments track the amplitude on a −60 to 0 dBFS display.

Calibration landmarks

Digital level (dBFS)Voltage (Vrms)Analog level (dBu)
09.7566722
-64.8899216
-122.4507710
-181.228294
-240.6156-2
-480.03884-26

Worked calculation

  1. Convert the input signal through RMS voltage

    4 dBu → 1.228292 Vrms. Vpp = 2√2 × 1.228292 = 3.474135 Vpp

  2. Find the analog voltage at digital full scale

    V0dBFS = 1.228292 ÷ 10^(-18 ÷ 20) = 9.75667 Vrms

  3. Map the voltage to the selected digital reference

    Digital level = 20 log₁₀(1.228292 ÷ 9.756672) = -18 dBFS

What the example shows

The console tone is about 1.228 Vrms and 3.474 Vpp. With this calibration, 18 more dB of sine amplitude reaches digital full scale.

Model assumptions

  • Peak-to-peak conversion assumes a clean sine wave. Program material has a changing crest factor and dBFS calibration here does not measure LUFS or true peak.
  • The EBU and SMPTE presets pair their digital reference levels with common analog alignment voltages. Use Custom to enter the reference measured on your converter.
  • An analog signal can map above 0 dBFS. This flags the amount above the chosen converter calibration limit.