−10 dBV Consumer Line Level to Volts and dBu

A consumer playback device quotes a −10 dBV nominal output. Use the 1 V dBV reference and translate it to the dBu scale to compare with professional equipment.

Inputs

Signal input
dBV
Converter calibration

Results

RMS voltage
0.31623Vrms
Level referenced to 0.775 Vrms
-7.79dBu
Sine peak-to-peak voltage
0.89443Vpp
Mapped digital level
-18dBFS
Remaining digital headroom
18dB
Level referenced to 1 Vrms
-10dBV
Analog voltage for 0 dBFS
2.5119Vrms
Analog reference voltage
0.3162Vrms
Calibration limit
Within full scale
Digital alignment meter
Digital alignment meterDigital amplitude (dBFS)Within full scale-60-48-36-24-120-10 dBV at -18 dBFS2.512 Vrms at full scale

The dashed marker indicates calibration. Illuminated segments track the amplitude on a −60 to 0 dBFS display.

Calibration landmarks

Digital level (dBFS)Voltage (Vrms)Analog level (dBu)
02.5118910.21
-61.258934.21
-120.63096-1.79
-180.31623-7.79
-240.15849-13.79
-480.01-37.79

Worked calculation

  1. Convert the input signal through RMS voltage

    -10 dBV → 0.316228 Vrms. Vpp = 2√2 × 0.316228 = 0.894427 Vpp

  2. Compare the two analog decibel references

    dBu = 20 log₁₀(Vrms ÷ 0.775) = -7.786. dBV = 20 log₁₀(Vrms ÷ 1) = -10

  3. Map the voltage to the selected digital reference

    Digital level = 20 log₁₀(0.316228 ÷ 2.511886) = -18 dBFS

What the example shows

−10 dBV is about 0.316 Vrms, or −7.79 dBu. The difference between the two scales follows from their distinct voltage references.

Model assumptions

  • Peak-to-peak conversion assumes a clean sine wave. Program material has a changing crest factor and dBFS calibration here does not measure LUFS or true peak.
  • The EBU and SMPTE presets pair their digital reference levels with common analog alignment voltages. Use Custom to enter the reference measured on your converter.
  • An analog signal can map above 0 dBFS. This flags the amount above the chosen converter calibration limit.