22 × 16 × 9 ft Home Theater Bass Modes and 80 Hz Crossover

A two-row theater uses an 80 Hz main-to-sub crossover. Plot the room through 125 Hz to see the low axial modes and the combinations that fall near the handoff.

Inputs

Room dimensions
ft
ft
ft
°F
Hz
Bass trap depth
Hz

Results

Lowest axial mode
25.61Hz
Quarter-wave depth
42.3in
Modes in plotted range
31
Short : middle : long
1 : 1.778 : 2.444
Bolt area (approx.)
Outside
Bonello density screen
Meets screen
Length mode
25.61Hz
Width mode
35.21Hz
Height mode
62.59Hz
Mode frequency distribution
Mode frequency distribution0255075100125AxialTangentialOblique25.6 HzFrequency (Hz)

Each stem marks a calculated resonance. Stem height increases where modes fall close together on the plot.

Bolt room proportion chart
Bolt room proportion chartLongest ÷ shortest11.21.41.61.8211.41.82.22.6Middle ÷ shortestPreferred regionYour room

The outline approximates Bolt’s historical preferred ratio region. The room point uses normalized, ordered dimensions.

Mode frequencies

Indices (p, q, r)TypeFrequency (Hz)
1, 0, 0Axial25.607
0, 1, 0Axial35.21
1, 1, 0Tangential43.537
2, 0, 0Axial51.214
2, 1, 0Tangential62.15
0, 0, 1Axial62.595
1, 0, 1Tangential67.63
0, 2, 0Axial70.419
0, 1, 1Tangential71.818
1, 2, 0Tangential74.93
1, 1, 1Oblique76.247
3, 0, 0Axial76.821
2, 0, 1Tangential80.876
3, 1, 0Tangential84.505
2, 2, 0Tangential87.073
2, 1, 1Oblique88.208
0, 2, 1Tangential94.218
1, 2, 1Oblique97.635
3, 0, 1Tangential99.094
4, 0, 0Axial102.428
3, 2, 0Tangential104.213
3, 1, 1Oblique105.163
0, 3, 0Axial105.629
2, 2, 1Oblique107.237
4, 1, 0Tangential108.311
1, 3, 0Tangential108.688
2, 3, 0Tangential117.389
4, 0, 1Tangential120.04
3, 2, 1Oblique121.566
0, 3, 1Tangential122.782
4, 2, 0Tangential124.299

Bonello density by band

Band center (Hz)ModesCoincidencesCheck
1000Meets screen
12.500Meets screen
1600Meets screen
2000Meets screen
2510Meets screen
31.510Meets screen
4010Meets screen
5010Meets screen
6340Meets screen
8080Meets screen
100100Meets screen
125190Meets screen
160360Meets screen
200710Meets screen

Worked calculation

  1. Find the lowest axial

    f = c ÷ (2 × longest side) = 343.42 ÷ (2 × 6.7056) = 25.607 Hz

  2. Add cross-axis modes

    f₁₁₀ = (c ÷ 2) × √[(1 ÷ 6.7056)² + (1 ÷ 4.8768)²] = 43.537 Hz

  3. Estimate porous trap depth

    d = c ÷ (4 × 80) = 1.073 m

What the example shows

The 22 ft first axial is around 25.6 Hz. Several orders land near the crossover, so measure each row with mains and subs separately and again with both active.

Model assumptions

  • Rigid rectangular boundaries are assumed. Frequencies locate possible resonances, while the source, listener and boundary losses determine their measured strength.
  • The Bonello screen uses complete third-octave bands from 10 to 200 Hz, independent of the plot limit. It permits equal counts and flags coincident modes in bands with fewer than five modes.
  • Bolt uses the shortest, middle and longest sides and a digitized outline. The quarter-wavelength result is a depth scale for porous treatment in air, and absorber construction affects performance.