10 × 10 × 8 ft Square Bedroom Modes at 56 Hz

The bedroom footprint is square. Use the mode table to distinguish the two axis labels even when their frequencies match, then check where the first tangential combination lands.

Inputs

Room dimensions
ft
ft
ft
°F
Hz
Bass trap depth

Results

Lowest axial mode
56.34Hz
Quarter-wave depth
60in
Modes in plotted range
16
Short : middle : long
1 : 1.25 : 1.25
Bolt area (approx.)
Outside
Bonello density screen
3 bands flagged
Length mode
56.34Hz
Width mode
56.34Hz
Height mode
70.42Hz
Mode frequency distribution
Mode frequency distribution0306090120150AxialTangentialOblique56.3 HzFrequency (Hz)

Each stem marks a calculated resonance. Stem height increases where modes fall close together on the plot.

Bolt room proportion chart
Bolt room proportion chartLongest ÷ shortest11.21.41.61.8211.41.82.22.6Middle ÷ shortestPreferred regionYour room

The outline approximates Bolt’s historical preferred ratio region. The room point uses normalized, ordered dimensions.

Mode frequencies

Indices (p, q, r)TypeFrequency (Hz)
1, 0, 0Axial56.335
0, 1, 0Axial56.335
0, 0, 1Axial70.419
1, 1, 0Tangential79.67
1, 0, 1Tangential90.18
0, 1, 1Tangential90.18
1, 1, 1Oblique106.331
2, 0, 0Axial112.671
0, 2, 0Axial112.671
2, 1, 0Tangential125.97
1, 2, 0Tangential125.97
2, 0, 1Tangential132.867
0, 2, 1Tangential132.867
0, 0, 2Axial140.838
2, 1, 1Oblique144.316
1, 2, 1Oblique144.316

Bonello density by band

Band center (Hz)ModesCoincidencesCheck
1000Meets screen
12.500Meets screen
1600Meets screen
2000Meets screen
2500Meets screen
31.500Meets screen
4000Meets screen
5000Meets screen
6331Coincident modes
8010Density drops
10031Coincident modes
12573Meets screen
160114Meets screen
200188Meets screen

Worked calculation

  1. Find the lowest axial

    f = c ÷ (2 × longest side) = 343.42 ÷ (2 × 3.048) = 56.335 Hz

  2. Add cross-axis modes

    f₁₁₀ = (c ÷ 2) × √[(1 ÷ 3.048)² + (1 ÷ 3.048)²] = 79.67 Hz

  3. Normalize by the shortest dimension

    1 : (3.048 ÷ 2.438) : (3.048 ÷ 2.438) ≈ 1 : 1.25 : 1.25

  4. Count the third-octave bands

    10–200 Hz centers → 0, 0, 0, 0, 0, 0, 0, 0, 3, 1, 3, 7, 11, 18 modes per band

What the example shows

The two 56 Hz rows are different spatial patterns. Speaker and listening positions can excite them differently even though a spectrum analyzer puts them at the same frequency.

Model assumptions

  • Rigid rectangular boundaries are assumed. Frequencies locate possible resonances, while the source, listener and boundary losses determine their measured strength.
  • The Bonello screen uses complete third-octave bands from 10 to 200 Hz, independent of the plot limit. It permits equal counts and flags coincident modes in bands with fewer than five modes.
  • Bolt uses the shortest, middle and longest sides and a digitized outline. The quarter-wavelength result is a depth scale for porous treatment in air, and absorber construction affects performance.