10 × 10 × 8 ft Square Bedroom Modes at 56 Hz
The bedroom footprint is square. Use the mode table to distinguish the two axis labels even when their frequencies match, then check where the first tangential combination lands.
- Length
- 10 ft
- Width
- 10 ft
- Height
- 8 ft
- Air temperature
- 68 °F
- Plot and table limit
- 150 Hz
- Frequency source
- Lowest axial mode
Results
- Lowest axial mode
- 56.34Hz
- Quarter-wave depth
- 60in
- Modes in plotted range
- 16
- Short : middle : long
- 1 : 1.25 : 1.25
- Bolt area (approx.)
- Outside
- Bonello density screen
- 3 bands flagged
- Length mode
- 56.34Hz
- Width mode
- 56.34Hz
- Height mode
- 70.42Hz
Each stem marks a calculated resonance. Stem height increases where modes fall close together on the plot.
The outline approximates Bolt’s historical preferred ratio region. The room point uses normalized, ordered dimensions.
Mode frequencies
| Indices (p, q, r) | Type | Frequency (Hz) |
|---|---|---|
| 1, 0, 0 | Axial | 56.335 |
| 0, 1, 0 | Axial | 56.335 |
| 0, 0, 1 | Axial | 70.419 |
| 1, 1, 0 | Tangential | 79.67 |
| 1, 0, 1 | Tangential | 90.18 |
| 0, 1, 1 | Tangential | 90.18 |
| 1, 1, 1 | Oblique | 106.331 |
| 2, 0, 0 | Axial | 112.671 |
| 0, 2, 0 | Axial | 112.671 |
| 2, 1, 0 | Tangential | 125.97 |
| 1, 2, 0 | Tangential | 125.97 |
| 2, 0, 1 | Tangential | 132.867 |
| 0, 2, 1 | Tangential | 132.867 |
| 0, 0, 2 | Axial | 140.838 |
| 2, 1, 1 | Oblique | 144.316 |
| 1, 2, 1 | Oblique | 144.316 |
Bonello density by band
| Band center (Hz) | Modes | Coincidences | Check |
|---|---|---|---|
| 10 | 0 | 0 | Meets screen |
| 12.5 | 0 | 0 | Meets screen |
| 16 | 0 | 0 | Meets screen |
| 20 | 0 | 0 | Meets screen |
| 25 | 0 | 0 | Meets screen |
| 31.5 | 0 | 0 | Meets screen |
| 40 | 0 | 0 | Meets screen |
| 50 | 0 | 0 | Meets screen |
| 63 | 3 | 1 | Coincident modes |
| 80 | 1 | 0 | Density drops |
| 100 | 3 | 1 | Coincident modes |
| 125 | 7 | 3 | Meets screen |
| 160 | 11 | 4 | Meets screen |
| 200 | 18 | 8 | Meets screen |
Worked calculation
Find the lowest axial
f = c ÷ (2 × longest side) = 343.42 ÷ (2 × 3.048) = 56.335 Hz
Add cross-axis modes
f₁₁₀ = (c ÷ 2) × √[(1 ÷ 3.048)² + (1 ÷ 3.048)²] = 79.67 Hz
Normalize by the shortest dimension
1 : (3.048 ÷ 2.438) : (3.048 ÷ 2.438) ≈ 1 : 1.25 : 1.25
Count the third-octave bands
10–200 Hz centers → 0, 0, 0, 0, 0, 0, 0, 0, 3, 1, 3, 7, 11, 18 modes per band
What the example shows
The two 56 Hz rows are different spatial patterns. Speaker and listening positions can excite them differently even though a spectrum analyzer puts them at the same frequency.
Model assumptions
- Rigid rectangular boundaries are assumed. Frequencies locate possible resonances, while the source, listener and boundary losses determine their measured strength.
- The Bonello screen uses complete third-octave bands from 10 to 200 Hz, independent of the plot limit. It permits equal counts and flags coincident modes in bands with fewer than five modes.
- Bolt uses the shortest, middle and longest sides and a digitized outline. The quarter-wavelength result is a depth scale for porous treatment in air, and absorber construction affects performance.
Common questions
Do the two 56 Hz modes in a square bedroom count as one?
They count as two modes with different spatial patterns and the same eigenfrequency. The Bonello table records a coincidence in their band.
What happens to the square-room double mode if I rotate the desk?
Desk orientation changes source and listener locations relative to the patterns. The room dimensions and the two matching eigenfrequencies stay the same.