6 × 4 × 2.5 m Control Room Modes Below 120 Hz

A project control room has 6 m between its end walls and 4 m across. Set a 120 Hz plot limit to inspect the lowest candidates without filling the plot with higher orders.

Inputs

Room dimensions
m
m
m
°C
Hz
Bass trap depth

Results

Lowest axial mode
28.62Hz
Quarter-wave depth
300cm
Modes in plotted range
21
Short : middle : long
1 : 1.6 : 2.4
Bolt area (approx.)
Inside
Bonello density screen
Meets screen
Length mode
28.62Hz
Width mode
42.93Hz
Height mode
68.68Hz
Mode frequency distribution
Mode frequency distribution024487296120AxialTangentialOblique28.6 HzFrequency (Hz)

Each stem marks a calculated resonance. Stem height increases where modes fall close together on the plot.

Bolt room proportion chart
Bolt room proportion chartLongest ÷ shortest11.21.41.61.8211.41.82.22.6Middle ÷ shortestPreferred regionYour room

The outline approximates Bolt’s historical preferred ratio region. The room point uses normalized, ordered dimensions.

Mode frequencies

Indices (p, q, r)TypeFrequency (Hz)
1, 0, 0Axial28.618
0, 1, 0Axial42.928
1, 1, 0Tangential51.592
2, 0, 0Axial57.237
0, 0, 1Axial68.684
2, 1, 0Tangential71.546
1, 0, 1Tangential74.408
0, 1, 1Tangential80.995
3, 0, 0Axial85.855
0, 2, 0Axial85.855
1, 1, 1Oblique85.903
2, 0, 1Tangential89.407
1, 2, 0Tangential90.499
3, 1, 0Tangential95.989
2, 1, 1Oblique99.178
2, 2, 0Tangential103.185
3, 0, 1Tangential109.948
0, 2, 1Tangential109.948
1, 2, 1Oblique113.612
4, 0, 0Axial114.473
3, 1, 1Oblique118.031

Bonello density by band

Band center (Hz)ModesCoincidencesCheck
1000Meets screen
12.500Meets screen
1600Meets screen
2000Meets screen
2500Meets screen
31.510Meets screen
4010Meets screen
5010Meets screen
6320Meets screen
8061Meets screen
10071Meets screen
125140Meets screen
160264Meets screen
200507Meets screen

Worked calculation

  1. Find the lowest axial

    f = c ÷ (2 × longest side) = 343.42 ÷ (2 × 6) = 28.618 Hz

  2. Add cross-axis modes

    f₁₁₀ = (c ÷ 2) × √[(1 ÷ 6)² + (1 ÷ 4)²] = 51.592 Hz

  3. Normalize by the shortest dimension

    1 : (4 ÷ 2.5) : (6 ÷ 2.5) ≈ 1 : 1.6 : 2.4

What the example shows

A 6 m length gives the first 28.6 Hz axial resonance. The 4 m width adds one around 42.9 Hz. Compare those with the 51.6 Hz length–width combination in the table.

Model assumptions

  • Rigid rectangular boundaries are assumed. Frequencies locate possible resonances, while the source, listener and boundary losses determine their measured strength.
  • The Bonello screen uses complete third-octave bands from 10 to 200 Hz, independent of the plot limit. It permits equal counts and flags coincident modes in bands with fewer than five modes.
  • Bolt uses the shortest, middle and longest sides and a digitized outline. The quarter-wavelength result is a depth scale for porous treatment in air, and absorber construction affects performance.