6 × 4 × 2.5 m Control Room Modes Below 120 Hz
A project control room has 6 m between its end walls and 4 m across. Set a 120 Hz plot limit to inspect the lowest candidates without filling the plot with higher orders.
- Length
- 6 m
- Width
- 4 m
- Height
- 2.5 m
- Air temperature
- 20 °C
- Plot and table limit
- 120 Hz
- Frequency source
- Lowest axial mode
Results
- Lowest axial mode
- 28.62Hz
- Quarter-wave depth
- 300cm
- Modes in plotted range
- 21
- Short : middle : long
- 1 : 1.6 : 2.4
- Bolt area (approx.)
- Inside
- Bonello density screen
- Meets screen
- Length mode
- 28.62Hz
- Width mode
- 42.93Hz
- Height mode
- 68.68Hz
Each stem marks a calculated resonance. Stem height increases where modes fall close together on the plot.
The outline approximates Bolt’s historical preferred ratio region. The room point uses normalized, ordered dimensions.
Mode frequencies
| Indices (p, q, r) | Type | Frequency (Hz) |
|---|---|---|
| 1, 0, 0 | Axial | 28.618 |
| 0, 1, 0 | Axial | 42.928 |
| 1, 1, 0 | Tangential | 51.592 |
| 2, 0, 0 | Axial | 57.237 |
| 0, 0, 1 | Axial | 68.684 |
| 2, 1, 0 | Tangential | 71.546 |
| 1, 0, 1 | Tangential | 74.408 |
| 0, 1, 1 | Tangential | 80.995 |
| 3, 0, 0 | Axial | 85.855 |
| 0, 2, 0 | Axial | 85.855 |
| 1, 1, 1 | Oblique | 85.903 |
| 2, 0, 1 | Tangential | 89.407 |
| 1, 2, 0 | Tangential | 90.499 |
| 3, 1, 0 | Tangential | 95.989 |
| 2, 1, 1 | Oblique | 99.178 |
| 2, 2, 0 | Tangential | 103.185 |
| 3, 0, 1 | Tangential | 109.948 |
| 0, 2, 1 | Tangential | 109.948 |
| 1, 2, 1 | Oblique | 113.612 |
| 4, 0, 0 | Axial | 114.473 |
| 3, 1, 1 | Oblique | 118.031 |
Bonello density by band
| Band center (Hz) | Modes | Coincidences | Check |
|---|---|---|---|
| 10 | 0 | 0 | Meets screen |
| 12.5 | 0 | 0 | Meets screen |
| 16 | 0 | 0 | Meets screen |
| 20 | 0 | 0 | Meets screen |
| 25 | 0 | 0 | Meets screen |
| 31.5 | 1 | 0 | Meets screen |
| 40 | 1 | 0 | Meets screen |
| 50 | 1 | 0 | Meets screen |
| 63 | 2 | 0 | Meets screen |
| 80 | 6 | 1 | Meets screen |
| 100 | 7 | 1 | Meets screen |
| 125 | 14 | 0 | Meets screen |
| 160 | 26 | 4 | Meets screen |
| 200 | 50 | 7 | Meets screen |
Worked calculation
Find the lowest axial
f = c ÷ (2 × longest side) = 343.42 ÷ (2 × 6) = 28.618 Hz
Add cross-axis modes
f₁₁₀ = (c ÷ 2) × √[(1 ÷ 6)² + (1 ÷ 4)²] = 51.592 Hz
Normalize by the shortest dimension
1 : (4 ÷ 2.5) : (6 ÷ 2.5) ≈ 1 : 1.6 : 2.4
What the example shows
A 6 m length gives the first 28.6 Hz axial resonance. The 4 m width adds one around 42.9 Hz. Compare those with the 51.6 Hz length–width combination in the table.
Model assumptions
- Rigid rectangular boundaries are assumed. Frequencies locate possible resonances, while the source, listener and boundary losses determine their measured strength.
- The Bonello screen uses complete third-octave bands from 10 to 200 Hz, independent of the plot limit. It permits equal counts and flags coincident modes in bands with fewer than five modes.
- Bolt uses the shortest, middle and longest sides and a digitized outline. The quarter-wavelength result is a depth scale for porous treatment in air, and absorber construction affects performance.
Common questions
Where does the 51.6 Hz mode come from in this control room?
It has a first-order component along both the 6 m length and the 4 m width. The squared contributions add inside the square root.
Does a 120 Hz plot limit change the control room’s Bonello result?
The plot and mode table stop at 120 Hz. The density check separately counts complete one-third-octave bands through the 200 Hz band.