Room Modes & Standing Waves Calculator
Find axial, tangential and oblique room modes, check Bolt and Bonello room proportions, and estimate quarter-wavelength bass trap depth.
- Length
- 15 ft
- Width
- 12 ft
- Height
- 8 ft
- Air temperature
- 68 °F
- Plot and table limit
- 200 Hz
- Frequency source
- Lowest axial mode
Results
- Lowest axial mode
- 37.56Hz
- Quarter-wave depth
- 90in
- Modes in plotted range
- 53
- Short : middle : long
- 1 : 1.5 : 1.875
- Bolt area (approx.)
- Inside
- Bonello density screen
- Meets screen
- Length mode
- 37.56Hz
- Width mode
- 46.95Hz
- Height mode
- 70.42Hz
Each stem marks a calculated resonance. Stem height increases where modes fall close together on the plot.
The outline approximates Bolt’s historical preferred ratio region. The room point uses normalized, ordered dimensions.
Mode frequencies
| Indices (p, q, r) | Type | Frequency (Hz) |
|---|---|---|
| 1, 0, 0 | Axial | 37.557 |
| 0, 1, 0 | Axial | 46.946 |
| 1, 1, 0 | Tangential | 60.12 |
| 0, 0, 1 | Axial | 70.419 |
| 2, 0, 0 | Axial | 75.114 |
| 1, 0, 1 | Tangential | 79.808 |
| 0, 1, 1 | Tangential | 84.633 |
| 2, 1, 0 | Tangential | 88.578 |
| 1, 1, 1 | Oblique | 92.592 |
| 0, 2, 0 | Axial | 93.892 |
| 1, 2, 0 | Tangential | 101.125 |
| 2, 0, 1 | Tangential | 102.961 |
| 3, 0, 0 | Axial | 112.671 |
| 2, 1, 1 | Oblique | 113.159 |
| 0, 2, 1 | Tangential | 117.365 |
| 2, 2, 0 | Tangential | 120.241 |
| 3, 1, 0 | Tangential | 122.06 |
| 1, 2, 1 | Oblique | 123.228 |
| 3, 0, 1 | Tangential | 132.867 |
| 2, 2, 1 | Oblique | 139.344 |
| 0, 3, 0 | Axial | 140.838 |
| 0, 0, 2 | Axial | 140.838 |
| 3, 1, 1 | Oblique | 140.916 |
| 1, 3, 0 | Tangential | 145.76 |
| 1, 0, 2 | Tangential | 145.76 |
| 3, 2, 0 | Tangential | 146.664 |
| 0, 1, 2 | Tangential | 148.457 |
| 4, 0, 0 | Axial | 150.227 |
| 1, 1, 2 | Oblique | 153.133 |
| 4, 1, 0 | Tangential | 157.392 |
| 0, 3, 1 | Tangential | 157.462 |
| 2, 3, 0 | Tangential | 159.617 |
| 2, 0, 2 | Tangential | 159.617 |
| 1, 3, 1 | Oblique | 161.879 |
| 3, 2, 1 | Oblique | 162.694 |
| 4, 0, 1 | Tangential | 165.913 |
| 2, 1, 2 | Oblique | 166.377 |
| 0, 2, 2 | Tangential | 169.267 |
| 4, 1, 1 | Oblique | 172.427 |
| 1, 2, 2 | Oblique | 173.383 |
| 2, 3, 1 | Oblique | 174.46 |
| 4, 2, 0 | Tangential | 177.155 |
| 3, 3, 0 | Tangential | 180.361 |
| 3, 0, 2 | Tangential | 180.361 |
| 2, 2, 2 | Oblique | 185.184 |
| 3, 1, 2 | Oblique | 186.371 |
| 0, 4, 0 | Axial | 187.784 |
| 5, 0, 0 | Axial | 187.784 |
| 4, 2, 1 | Oblique | 190.638 |
| 1, 4, 0 | Tangential | 191.503 |
| 5, 1, 0 | Tangential | 193.564 |
| 3, 3, 1 | Oblique | 193.621 |
| 0, 3, 2 | Tangential | 199.175 |
Bonello density by band
| Band center (Hz) | Modes | Coincidences | Check |
|---|---|---|---|
| 10 | 0 | 0 | Meets screen |
| 12.5 | 0 | 0 | Meets screen |
| 16 | 0 | 0 | Meets screen |
| 20 | 0 | 0 | Meets screen |
| 25 | 0 | 0 | Meets screen |
| 31.5 | 0 | 0 | Meets screen |
| 40 | 1 | 0 | Meets screen |
| 50 | 1 | 0 | Meets screen |
| 63 | 2 | 0 | Meets screen |
| 80 | 4 | 0 | Meets screen |
| 100 | 4 | 0 | Meets screen |
| 125 | 11 | 1 | Meets screen |
| 160 | 19 | 2 | Meets screen |
| 200 | 32 | 4 | Meets screen |
Calculation steps
Set sound speed
c = 331.3 + 0.606 × 20 = 343.42 m/s
Find the lowest axial
f = c ÷ (2 × longest side) = 343.42 ÷ (2 × 4.572) = 37.557 Hz
Add cross-axis modes
f₁₁₀ = (c ÷ 2) × √[(1 ÷ 4.572)² + (1 ÷ 3.6576)²] = 60.12 Hz
Estimate porous trap depth
d = c ÷ (4 × 37.557) = 2.286 m
Normalize by the shortest dimension
1 : (3.658 ÷ 2.438) : (4.572 ÷ 2.438) ≈ 1 : 1.5 : 1.875
Count the third-octave bands
10–200 Hz centers → 0, 0, 0, 0, 0, 0, 1, 1, 2, 4, 4, 11, 19, 32 modes per band
Model assumptions
- Rigid rectangular boundaries are assumed. Frequencies locate possible resonances, while the source, listener and boundary losses determine their measured strength.
- The Bonello screen uses complete third-octave bands from 10 to 200 Hz, independent of the plot limit. It permits equal counts and flags coincident modes in bands with fewer than five modes.
- Bolt uses the shortest, middle and longest sides and a digitized outline. The quarter-wavelength result is a depth scale for porous treatment in air, and absorber construction affects performance.
Common questions
How do I tell whether a mode is axial, tangential or oblique?
Count the nonzero indices p, q and r. One active axis gives an axial mode, two give a tangential mode and three give an oblique mode.
Can two different room modes have the same frequency?
Yes. Equal or simply related dimensions can make different index combinations land at the same frequency. The mode table keeps each combination and the density screen flags sparse bands with coincidences.
What does being inside the Bolt area tell me?
The three normalized dimensions fall within an approximate historical low-frequency spacing region. The calculation uses shape only. Bonello counts modes for the actual dimensions, and a room sweep shows the response at a particular position.