Bolt Area Check for a 1 : 1.5 : 2 Mixing Room
You can still move one end wall of a planned room. Start from 16 × 12 × 8 ft and see where the ratio dot moves as you edit the long dimension.
- Length
- 16 ft
- Width
- 12 ft
- Height
- 8 ft
- Air temperature
- 68 °F
- Plot and table limit
- 200 Hz
- Frequency source
- Lowest axial mode
Results
- Short : middle : long
- 1 : 1.5 : 2
- Bolt area (approx.)
- Inside
- Bonello density screen
- 3 bands flagged
- Lowest axial mode
- 35.21Hz
- Quarter-wave depth
- 96in
- Modes in plotted range
- 59
- Length mode
- 35.21Hz
- Width mode
- 46.95Hz
- Height mode
- 70.42Hz
Each stem marks a calculated resonance. Stem height increases where modes fall close together on the plot.
The outline approximates Bolt’s historical preferred ratio region. The room point uses normalized, ordered dimensions.
Mode frequencies
| Indices (p, q, r) | Type | Frequency (Hz) |
|---|---|---|
| 1, 0, 0 | Axial | 35.21 |
| 0, 1, 0 | Axial | 46.946 |
| 1, 1, 0 | Tangential | 58.683 |
| 2, 0, 0 | Axial | 70.419 |
| 0, 0, 1 | Axial | 70.419 |
| 1, 0, 1 | Tangential | 78.731 |
| 2, 1, 0 | Tangential | 84.633 |
| 0, 1, 1 | Tangential | 84.633 |
| 1, 1, 1 | Oblique | 91.665 |
| 0, 2, 0 | Axial | 93.892 |
| 2, 0, 1 | Tangential | 99.588 |
| 1, 2, 0 | Tangential | 100.277 |
| 3, 0, 0 | Axial | 105.629 |
| 2, 1, 1 | Oblique | 110.098 |
| 3, 1, 0 | Tangential | 115.591 |
| 2, 2, 0 | Tangential | 117.365 |
| 0, 2, 1 | Tangential | 117.365 |
| 1, 2, 1 | Oblique | 122.533 |
| 3, 0, 1 | Tangential | 126.95 |
| 3, 1, 1 | Oblique | 135.352 |
| 2, 2, 1 | Oblique | 136.87 |
| 4, 0, 0 | Axial | 140.838 |
| 0, 3, 0 | Axial | 140.838 |
| 0, 0, 2 | Axial | 140.838 |
| 3, 2, 0 | Tangential | 141.326 |
| 1, 3, 0 | Tangential | 145.173 |
| 1, 0, 2 | Tangential | 145.173 |
| 4, 1, 0 | Tangential | 148.457 |
| 0, 1, 2 | Tangential | 148.457 |
| 1, 1, 2 | Oblique | 152.575 |
| 4, 0, 1 | Tangential | 157.462 |
| 2, 3, 0 | Tangential | 157.462 |
| 2, 0, 2 | Tangential | 157.462 |
| 0, 3, 1 | Tangential | 157.462 |
| 3, 2, 1 | Oblique | 157.899 |
| 1, 3, 1 | Oblique | 161.35 |
| 4, 1, 1 | Oblique | 164.311 |
| 2, 1, 2 | Oblique | 164.311 |
| 4, 2, 0 | Tangential | 169.267 |
| 0, 2, 2 | Tangential | 169.267 |
| 2, 3, 1 | Oblique | 172.491 |
| 1, 2, 2 | Oblique | 172.89 |
| 3, 3, 0 | Tangential | 176.048 |
| 3, 0, 2 | Tangential | 176.048 |
| 5, 0, 0 | Axial | 176.048 |
| 5, 1, 0 | Tangential | 182.2 |
| 3, 1, 2 | Oblique | 182.2 |
| 4, 2, 1 | Oblique | 183.33 |
| 2, 2, 2 | Oblique | 183.33 |
| 0, 4, 0 | Axial | 187.784 |
| 5, 0, 1 | Tangential | 189.609 |
| 3, 3, 1 | Oblique | 189.609 |
| 1, 4, 0 | Tangential | 191.057 |
| 5, 1, 1 | Oblique | 195.335 |
| 4, 3, 0 | Tangential | 199.175 |
| 4, 0, 2 | Tangential | 199.175 |
| 0, 3, 2 | Tangential | 199.175 |
| 5, 2, 0 | Tangential | 199.521 |
| 3, 2, 2 | Oblique | 199.521 |
Bonello density by band
| Band center (Hz) | Modes | Coincidences | Check |
|---|---|---|---|
| 10 | 0 | 0 | Meets screen |
| 12.5 | 0 | 0 | Meets screen |
| 16 | 0 | 0 | Meets screen |
| 20 | 0 | 0 | Meets screen |
| 25 | 0 | 0 | Meets screen |
| 31.5 | 1 | 0 | Meets screen |
| 40 | 0 | 0 | Density drops |
| 50 | 1 | 0 | Meets screen |
| 63 | 3 | 1 | Coincident modes |
| 80 | 3 | 1 | Coincident modes |
| 100 | 6 | 0 | Meets screen |
| 125 | 11 | 3 | Meets screen |
| 160 | 20 | 9 | Meets screen |
| 200 | 33 | 12 | Meets screen |
Worked calculation
Normalize by the shortest dimension
1 : (3.658 ÷ 2.438) : (4.877 ÷ 2.438) ≈ 1 : 1.5 : 2
Find the lowest axial
f = c ÷ (2 × longest side) = 343.42 ÷ (2 × 4.8768) = 35.21 Hz
Count the third-octave bands
10–200 Hz centers → 0, 0, 0, 0, 0, 1, 0, 1, 3, 3, 6, 11, 20, 33 modes per band
What the example shows
The Bolt chart looks only at proportions. The 16 ft second-order length mode and 8 ft first-order height mode coincide near 70.4 Hz, an example of the extra detail in the numbered table.
Model assumptions
- Rigid rectangular boundaries are assumed. Frequencies locate possible resonances, while the source, listener and boundary losses determine their measured strength.
- The Bonello screen uses complete third-octave bands from 10 to 200 Hz, independent of the plot limit. It permits equal counts and flags coincident modes in bands with fewer than five modes.
- Bolt uses the shortest, middle and longest sides and a digitized outline. The quarter-wavelength result is a depth scale for porous treatment in air, and absorber construction affects performance.
Common questions
Why do 16 ft and 8 ft give matching modes at 70.4 Hz?
The long side’s second harmonic equals the short side’s fundamental because the long side is exactly twice as long.
If I scale 8 × 12 × 16 ft up by 25%, does the Bolt marker move?
No. The dimension ratios are identical. Individual modal frequencies fall to 80% of their original values and the density bands can change.