Bolt Area Check for a 1 : 1.5 : 2 Mixing Room

You can still move one end wall of a planned room. Start from 16 × 12 × 8 ft and see where the ratio dot moves as you edit the long dimension.

Inputs

Room dimensions
ft
ft
ft
°F
Hz
Bass trap depth

Results

Short : middle : long
1 : 1.5 : 2
Bolt area (approx.)
Inside
Bonello density screen
3 bands flagged
Lowest axial mode
35.21Hz
Quarter-wave depth
96in
Modes in plotted range
59
Length mode
35.21Hz
Width mode
46.95Hz
Height mode
70.42Hz
Mode frequency distribution
Mode frequency distribution04080120160200AxialTangentialOblique35.2 HzFrequency (Hz)

Each stem marks a calculated resonance. Stem height increases where modes fall close together on the plot.

Bolt room proportion chart
Bolt room proportion chartLongest ÷ shortest11.21.41.61.8211.41.82.22.6Middle ÷ shortestPreferred regionYour room

The outline approximates Bolt’s historical preferred ratio region. The room point uses normalized, ordered dimensions.

Mode frequencies

Indices (p, q, r)TypeFrequency (Hz)
1, 0, 0Axial35.21
0, 1, 0Axial46.946
1, 1, 0Tangential58.683
2, 0, 0Axial70.419
0, 0, 1Axial70.419
1, 0, 1Tangential78.731
2, 1, 0Tangential84.633
0, 1, 1Tangential84.633
1, 1, 1Oblique91.665
0, 2, 0Axial93.892
2, 0, 1Tangential99.588
1, 2, 0Tangential100.277
3, 0, 0Axial105.629
2, 1, 1Oblique110.098
3, 1, 0Tangential115.591
2, 2, 0Tangential117.365
0, 2, 1Tangential117.365
1, 2, 1Oblique122.533
3, 0, 1Tangential126.95
3, 1, 1Oblique135.352
2, 2, 1Oblique136.87
4, 0, 0Axial140.838
0, 3, 0Axial140.838
0, 0, 2Axial140.838
3, 2, 0Tangential141.326
1, 3, 0Tangential145.173
1, 0, 2Tangential145.173
4, 1, 0Tangential148.457
0, 1, 2Tangential148.457
1, 1, 2Oblique152.575
4, 0, 1Tangential157.462
2, 3, 0Tangential157.462
2, 0, 2Tangential157.462
0, 3, 1Tangential157.462
3, 2, 1Oblique157.899
1, 3, 1Oblique161.35
4, 1, 1Oblique164.311
2, 1, 2Oblique164.311
4, 2, 0Tangential169.267
0, 2, 2Tangential169.267
2, 3, 1Oblique172.491
1, 2, 2Oblique172.89
3, 3, 0Tangential176.048
3, 0, 2Tangential176.048
5, 0, 0Axial176.048
5, 1, 0Tangential182.2
3, 1, 2Oblique182.2
4, 2, 1Oblique183.33
2, 2, 2Oblique183.33
0, 4, 0Axial187.784
5, 0, 1Tangential189.609
3, 3, 1Oblique189.609
1, 4, 0Tangential191.057
5, 1, 1Oblique195.335
4, 3, 0Tangential199.175
4, 0, 2Tangential199.175
0, 3, 2Tangential199.175
5, 2, 0Tangential199.521
3, 2, 2Oblique199.521

Bonello density by band

Band center (Hz)ModesCoincidencesCheck
1000Meets screen
12.500Meets screen
1600Meets screen
2000Meets screen
2500Meets screen
31.510Meets screen
4000Density drops
5010Meets screen
6331Coincident modes
8031Coincident modes
10060Meets screen
125113Meets screen
160209Meets screen
2003312Meets screen

Worked calculation

  1. Normalize by the shortest dimension

    1 : (3.658 ÷ 2.438) : (4.877 ÷ 2.438) ≈ 1 : 1.5 : 2

  2. Find the lowest axial

    f = c ÷ (2 × longest side) = 343.42 ÷ (2 × 4.8768) = 35.21 Hz

  3. Count the third-octave bands

    10–200 Hz centers → 0, 0, 0, 0, 0, 1, 0, 1, 3, 3, 6, 11, 20, 33 modes per band

What the example shows

The Bolt chart looks only at proportions. The 16 ft second-order length mode and 8 ft first-order height mode coincide near 70.4 Hz, an example of the extra detail in the numbered table.

Model assumptions

  • Rigid rectangular boundaries are assumed. Frequencies locate possible resonances, while the source, listener and boundary losses determine their measured strength.
  • The Bonello screen uses complete third-octave bands from 10 to 200 Hz, independent of the plot limit. It permits equal counts and flags coincident modes in bands with fewer than five modes.
  • Bolt uses the shortest, middle and longest sides and a digitized outline. The quarter-wavelength result is a depth scale for porous treatment in air, and absorber construction affects performance.