Bonello Density for an 18 × 13 × 9 ft Recording Room

The studio is long enough to place its first resonance near the 31.5 Hz band. Use the band counts to see where the sequence stalls or drops as more cross-axis modes enter.

Inputs

Room dimensions
ft
ft
ft
°F
Hz
Bass trap depth

Results

Bonello density screen
1 band flagged
Lowest axial mode
31.3Hz
Modes in plotted range
101
Quarter-wave depth
108in
Short : middle : long
1 : 1.444 : 2
Bolt area (approx.)
Inside
Length mode
31.3Hz
Width mode
43.33Hz
Height mode
62.59Hz
Mode frequency distribution
Mode frequency distribution04488132176220AxialTangentialOblique31.3 HzFrequency (Hz)

Each stem marks a calculated resonance. Stem height increases where modes fall close together on the plot.

Bolt room proportion chart
Bolt room proportion chartLongest ÷ shortest11.21.41.61.8211.41.82.22.6Middle ÷ shortestPreferred regionYour room

The outline approximates Bolt’s historical preferred ratio region. The room point uses normalized, ordered dimensions.

Mode frequencies

Indices (p, q, r)TypeFrequency (Hz)
1, 0, 0Axial31.297
0, 1, 0Axial43.335
1, 1, 0Tangential53.455
2, 0, 0Axial62.595
0, 0, 1Axial62.595
1, 0, 1Tangential69.983
2, 1, 0Tangential76.132
0, 1, 1Tangential76.132
1, 1, 1Oblique82.314
0, 2, 0Axial86.67
2, 0, 1Tangential88.522
1, 2, 0Tangential92.148
3, 0, 0Axial93.892
2, 1, 1Oblique98.56
3, 1, 0Tangential103.41
2, 2, 0Tangential106.91
0, 2, 1Tangential106.91
1, 2, 1Oblique111.397
3, 0, 1Tangential112.844
3, 1, 1Oblique120.879
2, 2, 1Oblique123.886
4, 0, 0Axial125.19
0, 0, 2Axial125.19
3, 2, 0Tangential127.779
1, 0, 2Tangential129.042
0, 3, 0Axial130.005
4, 1, 0Tangential132.478
0, 1, 2Tangential132.478
1, 3, 0Tangential133.719
1, 1, 2Oblique136.124
4, 0, 1Tangential139.966
2, 0, 2Tangential139.966
3, 2, 1Oblique142.287
2, 3, 0Tangential144.289
0, 3, 1Tangential144.289
4, 1, 1Oblique146.521
2, 1, 2Oblique146.521
1, 3, 1Oblique147.644
4, 2, 0Tangential152.263
0, 2, 2Tangential152.263
1, 2, 2Oblique155.446
5, 0, 0Axial156.487
3, 0, 2Tangential156.487
2, 3, 1Oblique157.281
3, 3, 0Tangential160.365
3, 1, 2Oblique162.376
5, 1, 0Tangential162.376
4, 2, 1Oblique164.627
2, 2, 2Oblique164.627
5, 0, 1Tangential168.542
3, 3, 1Oblique172.148
0, 4, 0Axial173.339
5, 1, 1Oblique174.024
1, 4, 0Tangential176.142
4, 0, 2Tangential177.045
5, 2, 0Tangential178.885
3, 2, 2Oblique178.885
4, 3, 0Tangential180.482
0, 3, 2Tangential180.482
4, 1, 2Oblique182.271
1, 3, 2Oblique183.175
2, 4, 0Tangential184.295
0, 4, 1Tangential184.295
1, 4, 1Oblique186.934
6, 0, 0Axial187.784
0, 0, 3Axial187.784
5, 2, 1Oblique189.52
1, 0, 3Tangential190.375
4, 3, 1Oblique191.028
2, 3, 2Oblique191.028
6, 1, 0Tangential192.72
0, 1, 3Tangential192.72
2, 4, 1Oblique194.635
1, 1, 3Oblique195.244
4, 2, 2Oblique197.12
3, 4, 0Tangential197.135
6, 0, 1Tangential197.942
2, 0, 3Tangential197.942
5, 0, 2Tangential200.401
6, 1, 1Oblique202.63

Showing the first 80 of 101 rows. Download CSV for the full table.

Bonello density by band

Band center (Hz)ModesCoincidencesCheck
1000Meets screen
12.500Meets screen
1600Meets screen
2000Meets screen
2500Meets screen
31.510Meets screen
4010Meets screen
5010Meets screen
6331Coincident modes
8051Meets screen
10071Meets screen
125143Meets screen
160236Meets screen
2004913Meets screen

Worked calculation

  1. Find the lowest axial

    f = c ÷ (2 × longest side) = 343.42 ÷ (2 × 5.4864) = 31.297 Hz

  2. Normalize by the shortest dimension

    1 : (3.962 ÷ 2.743) : (5.486 ÷ 2.743) ≈ 1 : 1.444 : 2

  3. Count the third-octave bands

    10–200 Hz centers → 0, 0, 0, 0, 0, 1, 1, 1, 3, 5, 7, 14, 23, 49 modes per band

What the example shows

A flagged band suggests a more detailed measurement around that range. Frequencies alone cannot tell you how long a particular resonance rings.

Model assumptions

  • Rigid rectangular boundaries are assumed. Frequencies locate possible resonances, while the source, listener and boundary losses determine their measured strength.
  • The Bonello screen uses complete third-octave bands from 10 to 200 Hz, independent of the plot limit. It permits equal counts and flags coincident modes in bands with fewer than five modes.
  • Bolt uses the shortest, middle and longest sides and a digitized outline. The quarter-wavelength result is a depth scale for porous treatment in air, and absorber construction affects performance.