Sealed vs. 27 Hz Ported Response for a 15-Inch Sub
Hold both versions of a 15-inch cabinet to 4.0 ft³ net and tune the vented one to 27 Hz. Compare the bass transition without changing driver parameters.
- Driver resonance (Fs)
- 23 Hz
- Driver total Q (Qts)
- 0.36
- Driver equivalent volume (Vas)
- 6 ft³
- Target sealed Qtc
- 0.707
- Solve for
- Port length from net volume
- Net internal volume
- 4 ft³
- Port tuning (Fb)
- 27 Hz
- Port shape
- Round tube
- Inside tube diameter
- 6 in
- Identical ports
- 1
- Port end correction
- One flanged, one free
- Peak volume flow through all ports
- 7.41608 ft³/s
- Peak Mach limit
- 0.05
- Air temperature
- 68 °F
Results
- Physical port length per duct
- 21.6in
- Net modeled enclosure volume
- 4ft³
- Peak port Mach number
- 0.0335
- Sealed system Qtc
- 0.569
- Sealed −3 dB frequency
- 47.15Hz
- Sealed box for target Qtc
- 2.1ft³
- Total open port area
- 28.27in²
- Estimated peak port air speed
- 37.77ft/s
- Area needed at entered Mach limit
- 18.96in²
- Mach screen
- Within limit
- Port duct displacement
- 0.35ft³
The cross-section is schematic. The duct span responds to the computed length, and the Mach reading uses the entered airflow.
Small-signal curves normalized to the upper passband. The dashed line marks the target port tuning.
Small-signal response
| Frequency (Hz) | Sealed (dB) | Vented (dB) |
|---|---|---|
| 7.67 | -27.26 | -41.78 |
| 23 | -9.99 | -5.25 |
| 27 | -7.97 | -0.74 |
| 47.15 | -3.01 | 0.69 |
| 80 | -1.03 | 0.11 |
| 120 | -0.45 | 0.03 |
Worked calculation
Find sealed resonance and damping
Qtc = 0.36 × √(1 + 169.901 ÷ 113.267) = 0.5692. Fc = 36.366 Hz. Solving |H| = 1/√2 gives F₃ = 47.153 Hz
Subtract the end correction from effective duct length
L = S(c ÷ 2πFb)² ÷ Vb − ΔL = 65.996 − 11.125 = 54.871 cm
Check peak air velocity
u = 0.21 m³/s ÷ 0.0182415 m² = 11.512 m/s. Mach = u ÷ 343.42 = 0.03352
What the example shows
The vented trace can add output around tuning and falls faster below it. Choice of high-pass protection and power depends on excursion and air speed in the final system.
Model assumptions
- Use net internal air volume after removing the displacement of the driver, braces and port. The listed vent displacement covers the air duct, with wall material handled separately.
- The sealed and vented curves assume small signals. The vented curve includes driver Qts and ideal Helmholtz behavior. Confirm real tuning and excursion with a measurement or a driver model that includes losses.
- Air speed uses peak volume flow at the port, supplied from a measurement or a simulation at your target level. The Mach limit is an editable design screen. Slot end correction uses an equivalent round radius.
Common questions
Which curve falls faster below 27 Hz in this 15-inch example?
The vented alignment tends toward 24 dB per octave at low frequencies. The sealed alignment tends toward 12 dB per octave.
Does the 4 ft³ comparison include cabin gain or a DSP boost?
Both curves show the ideal small-signal alignment alone. Add the effects of the listening space and electronics in the measurements or a fuller simulation.