F3 of a 0.75 ft³ Sealed Subwoofer Box

A compact sealed build is limited to 0.75 ft³ net. Enter the driver’s measured or specified parameters and read the low-frequency half-power crossing.

Inputs

Driver and sealed alignment
Hz
ft³
Vented box and port
ft³
Hz
in
in
Air-speed check
ft³/s
°F

Results

Sealed −3 dB frequency
55.96Hz
Sealed system Qtc
0.673
Net modeled enclosure volume
0.75ft³
Physical port length per duct
43.3in
Peak port Mach number
0.0384
Sealed box for target Qtc
0.65ft³
Total open port area
20in²
Estimated peak port air speed
43.23ft/s
Area needed at entered Mach limit
15.35in²
Mach screen
Within limit
Port duct displacement
0.5ft³
Enclosure and duct section
Enclosure and duct sectionNet air volume0.75 ft³1 × slot · 39 Hz43.3 in per ductMach 0.0384Limit 0.05

The cross-section is schematic. The duct span responds to the computed length, and the Mach reading uses the entered airflow.

Sealed and vented response
Sealed and vented responseRelative level (dB)10214493195-48-36-24-1201224Frequency (Hz)VentedSealed

Small-signal curves normalized to the upper passband. The dashed line marks the target port tuning.

Small-signal response

Frequency (Hz)Sealed (dB)Vented (dB)
10-29.04-43.33
30-10.6-8.95
39-6.84-2.02
55.96-3.012.31
80-1.091.6
120-0.330.74

Worked calculation

  1. Find sealed resonance and damping

    Qtc = 0.38 × √(1 + 45.307 ÷ 21.238) = 0.6726. Fc = 53.104 Hz. Solving |H| = 1/√2 gives F₃ = 55.963 Hz

  2. Find net volume for the sealed target

    Vb = Vas ÷ [(Qtc ÷ Qts)² − 1] = 45.307 ÷ [(0.707 ÷ 0.38)² − 1] = 18.406 L

What the example shows

Watch both Fc and F3. They coincide only near Qtc 0.707. A lower-Q box has a more gradual transition with F3 above resonance.

Model assumptions

  • Use net internal air volume after removing the displacement of the driver, braces and port. The listed vent displacement covers the air duct, with wall material handled separately.
  • The sealed and vented curves assume small signals. The vented curve includes driver Qts and ideal Helmholtz behavior. Confirm real tuning and excursion with a measurement or a driver model that includes losses.
  • Air speed uses peak volume flow at the port, supplied from a measurement or a simulation at your target level. The Mach limit is an editable design screen. Slot end correction uses an equivalent round radius.