F3 of a 0.75 ft³ Sealed Subwoofer Box
A compact sealed build is limited to 0.75 ft³ net. Enter the driver’s measured or specified parameters and read the low-frequency half-power crossing.
- Driver resonance (Fs)
- 30 Hz
- Driver total Q (Qts)
- 0.38
- Driver equivalent volume (Vas)
- 1.6 ft³
- Target sealed Qtc
- 0.707
- Solve for
- Port length from net volume
- Net internal volume
- 0.75 ft³
- Port tuning (Fb)
- 39 Hz
- Port shape
- Rectangular slot
- Inside slot width
- 10 in
- Inside slot height
- 2 in
- Identical ports
- 1
- Port end correction
- One flanged, one free
- Peak volume flow through all ports
- 6.003493 ft³/s
- Peak Mach limit
- 0.05
- Air temperature
- 68 °F
Results
- Sealed −3 dB frequency
- 55.96Hz
- Sealed system Qtc
- 0.673
- Net modeled enclosure volume
- 0.75ft³
- Physical port length per duct
- 43.3in
- Peak port Mach number
- 0.0384
- Sealed box for target Qtc
- 0.65ft³
- Total open port area
- 20in²
- Estimated peak port air speed
- 43.23ft/s
- Area needed at entered Mach limit
- 15.35in²
- Mach screen
- Within limit
- Port duct displacement
- 0.5ft³
The cross-section is schematic. The duct span responds to the computed length, and the Mach reading uses the entered airflow.
Small-signal curves normalized to the upper passband. The dashed line marks the target port tuning.
Small-signal response
| Frequency (Hz) | Sealed (dB) | Vented (dB) |
|---|---|---|
| 10 | -29.04 | -43.33 |
| 30 | -10.6 | -8.95 |
| 39 | -6.84 | -2.02 |
| 55.96 | -3.01 | 2.31 |
| 80 | -1.09 | 1.6 |
| 120 | -0.33 | 0.74 |
Worked calculation
Find sealed resonance and damping
Qtc = 0.38 × √(1 + 45.307 ÷ 21.238) = 0.6726. Fc = 53.104 Hz. Solving |H| = 1/√2 gives F₃ = 55.963 Hz
Find net volume for the sealed target
Vb = Vas ÷ [(Qtc ÷ Qts)² − 1] = 45.307 ÷ [(0.707 ÷ 0.38)² − 1] = 18.406 L
What the example shows
Watch both Fc and F3. They coincide only near Qtc 0.707. A lower-Q box has a more gradual transition with F3 above resonance.
Model assumptions
- Use net internal air volume after removing the displacement of the driver, braces and port. The listed vent displacement covers the air duct, with wall material handled separately.
- The sealed and vented curves assume small signals. The vented curve includes driver Qts and ideal Helmholtz behavior. Confirm real tuning and excursion with a measurement or a driver model that includes losses.
- Air speed uses peak volume flow at the port, supplied from a measurement or a simulation at your target level. The Mach limit is an editable design screen. Slot end correction uses an equivalent round radius.
Common questions
Is the 30 Hz free-air Fs the −3 dB point of this 0.75 ft³ box?
No. The trapped air raises the system resonance and changes Q, which together determine F3.
What happens to sealed Qtc if I make this box smaller?
The air spring stiffens, raising the resonant frequency and system Q. Edit net volume to see how both values change.