Port Mach Check at 200 L/s Peak Flow

A driver simulation puts peak airflow near 200 L/s at the loudest test tone. Compare a 250 × 40 mm slot with a Mach 0.05 limit before finalizing the port.

Inputs

Driver and sealed alignment
Hz
L
Vented box and port
L
Hz
cm
cm
Air-speed check
L/s
°C

Results

Peak port Mach number
0.0582
Estimated peak port air speed
20m/s
Area needed at entered Mach limit
116.48cm²
Physical port length per duct
35.31cm
Net modeled enclosure volume
56L
Sealed system Qtc
0.653
Sealed −3 dB frequency
47.44Hz
Sealed box for target Qtc
43.24L
Total open port area
100cm²
Mach screen
Above limit
Port duct displacement
3.53L
Enclosure and duct section
Enclosure and duct sectionNet air volume56 L1 × slot · 35 Hz35.31 cm per ductMach 0.0582Limit 0.05

The cross-section is schematic. The duct span responds to the computed length, and the Mach reading uses the entered airflow.

Sealed and vented response
Sealed and vented responseRelative level (dB)9194084175-48-36-24-1201224Frequency (Hz)VentedSealed

Small-signal curves normalized to the upper passband. The dashed line marks the target port tuning.

Small-signal response

Frequency (Hz)Sealed (dB)Vented (dB)
9.33-26.82-42.34
28-8.85-5.8
35-5.940.86
47.44-3.013.48
80-0.761.3
120-0.260.56

Worked calculation

  1. Calculate the total open area

    S = 1 × 25 × 4 = 100 cm²

  2. Check peak air velocity

    u = 0.2 m³/s ÷ 0.01 m² = 20 m/s. Mach = u ÷ 343.42 = 0.05824

  3. Subtract the end correction from effective duct length

    L = S(c ÷ 2πFb)² ÷ Vb − ΔL = 43.548 − 8.237 = 35.311 cm

What the example shows

That 100 cm² opening gives 20 m/s and about Mach 0.058. The minimum area at Mach 0.05 is about 116 cm², and increasing area also changes the tuning length.

Model assumptions

  • Use net internal air volume after removing the displacement of the driver, braces and port. The listed vent displacement covers the air duct, with wall material handled separately.
  • The sealed and vented curves assume small signals. The vented curve includes driver Qts and ideal Helmholtz behavior. Confirm real tuning and excursion with a measurement or a driver model that includes losses.
  • Air speed uses peak volume flow at the port, supplied from a measurement or a simulation at your target level. The Mach limit is an editable design screen. Slot end correction uses an equivalent round radius.