EBU −18 dBFS Tone at 0 dBu

A transfer session pairs the −18 dBFS alignment tone with a 0 dBu analog reference. Translate that signal to volts and see the implied converter limit.

Inputs

Signal input
dBFS
Converter calibration

Results

RMS voltage
0.775Vrms
Analog voltage for 0 dBFS
6.156Vrms
Level referenced to 0.775 Vrms
0dBu
Mapped digital level
-18dBFS
Remaining digital headroom
18dB
Level referenced to 1 Vrms
-2.21dBV
Sine peak-to-peak voltage
2.19203Vpp
Analog reference voltage
0.775Vrms
Calibration limit
Within full scale
Digital alignment meter
Digital alignment meterDigital amplitude (dBFS)Within full scale-60-48-36-24-1200 dBu at -18 dBFS6.156 Vrms at full scale

The dashed marker indicates calibration. Illuminated segments track the amplitude on a −60 to 0 dBFS display.

Calibration landmarks

Digital level (dBFS)Voltage (Vrms)Analog level (dBu)
06.1560418
-63.0853312
-121.546336
-180.7750
-240.38842-6
-480.02451-30

Worked calculation

  1. Convert the reference tone to voltage

    Vref = 0.775 × 10^(0 ÷ 20) = 0.775 Vrms

  2. Find the analog voltage at digital full scale

    V0dBFS = 0.775 ÷ 10^(-18 ÷ 20) = 6.15604 Vrms

  3. Convert the input signal through RMS voltage

    -18 dBFS → 0.775 Vrms. Vpp = 2√2 × 0.775 = 2.192031 Vpp

What the example shows

The −18 dBFS tone maps to 0.775 Vrms with that analog setting. The preset implies about 6.16 Vrms at 0 dBFS.

Model assumptions

  • Peak-to-peak conversion assumes a clean sine wave. Program material has a changing crest factor and dBFS calibration here does not measure LUFS or true peak.
  • The EBU and SMPTE presets pair their digital reference levels with common analog alignment voltages. Use Custom to enter the reference measured on your converter.
  • An analog signal can map above 0 dBFS. This flags the amount above the chosen converter calibration limit.