−20 dBFS SMPTE Alignment Tone to +4 dBu

Play a −20 dBFS digital alignment sine into a converter using a common +4 dBu analog reference. Calculate the analog output and available headroom.

Inputs

Signal input
dBFS
Converter calibration

Results

Level referenced to 0.775 Vrms
4dBu
RMS voltage
1.22829Vrms
Analog voltage for 0 dBFS
12.2829Vrms
Mapped digital level
-20dBFS
Remaining digital headroom
20dB
Level referenced to 1 Vrms
1.79dBV
Sine peak-to-peak voltage
3.47414Vpp
Analog reference voltage
1.2283Vrms
Calibration limit
Within full scale
Digital alignment meter
Digital alignment meterDigital amplitude (dBFS)Within full scale-60-48-36-24-1204 dBu at -20 dBFS12.283 Vrms at full scale

The dashed marker indicates calibration. Illuminated segments track the amplitude on a −60 to 0 dBFS display.

Calibration landmarks

Digital level (dBFS)Voltage (Vrms)Analog level (dBu)
012.2829224
-66.1560418
-123.0853312
-201.228294
-240.7751.93e-15
-480.0489-24

Worked calculation

  1. Convert the reference tone to voltage

    Vref = 0.775 × 10^(4 ÷ 20) = 1.228292 Vrms

  2. Find the analog voltage at digital full scale

    V0dBFS = 1.228292 ÷ 10^(-20 ÷ 20) = 12.28292 Vrms

  3. Convert the input signal through RMS voltage

    -20 dBFS → 1.228292 Vrms. Vpp = 2√2 × 1.228292 = 3.474135 Vpp

What the example shows

The analog alignment tone is about 1.228 Vrms. A 20 dB amplitude difference represents a factor of ten in voltage.

Model assumptions

  • Peak-to-peak conversion assumes a clean sine wave. Program material has a changing crest factor and dBFS calibration here does not measure LUFS or true peak.
  • The EBU and SMPTE presets pair their digital reference levels with common analog alignment voltages. Use Custom to enter the reference measured on your converter.
  • An analog signal can map above 0 dBFS. This flags the amount above the chosen converter calibration limit.